20
6.10
Configuration and System settings
Menu level 1
Menu level 2
Menu level 3
description
el
ConFIG
System configuration
CM
fuel compensation
2
oFF
compensation off
2
dbL OIL
double fuel compensation (e.g. Diesel / HFO)
2
FL
medium/fluid selection for compensation
1
dFO
destillate fuel oil (e.g. Diesel)
1
HFO
heavy fuel oil (e.g. HFO)
1
tr
temperature reference (
15°C
)
tt
temperature threshold (
60°C
, 20-90)
2
dd
destillate fuel density (
830kg/m3
, 800-1200)
2
hd
heavy fuel density (
998kg/m3
, 800-1200)
2
dC
destillate fuel carbon index Co2 (
3.206
, 2-4)
2
hC
heavy fuel carbon index Co2 (
3.1144
, 2-4)
2
SGL OIL
single fuel compensation (e.g. Diesel or Lube)
2
FL
medium/fluid selection for compensation
1
dFO
destillate fuel oil
1
HFO
heavy fuel oil
1
LubE
lube oil
1
tr
temperature reference (
15°C
)
dd
destillate fuel density (
830kg/m3
, 800-1200)
2
dC
destillate fuel carbon index Co2 (
3.206
, 2-4)
2
LF
low flow cut off (
Qstart of DN
, 0-Qmin)
2
dQ
damping of instant flow values (
10
, 0-99)
1
dt
damping of temperature values (
10
, 0-99)
1
SYS-SEt
System settings
dA
system date (dd.mm.yy)
1
ti
system time (hh:mm)
1
dY
weekday
dS
daylight saving time:
oFF
/ Add 1h
1
Mo
select mode
SINGLE
single flow meter mode
Co
00001111
edit user code, reset with manager code only (el3)
1
rE
system reset
0
CANCEL
cancel reset
0
ALArM
reset all alarms
4
CountEr
reset all counters
4
LoGGEr
reset all loggers
4
dEFAULt
reset to default values
4
FACtorY
reset all settings to factory default
5
rtC rES
reset RTC clock
5
CI rES
reset customer initializing date
4
SI
simulation of complete system
4
oFF
simulation
off
/ on
4
SI
#.###
value to be simulated
4