POSITIONING YOUR FILTER
Choose a location where any water spillage will not cause damage. Make sure mounting position is solid so that the filter housing
stays in position when changing filters. An isolation valve may be installed immediately prior to the filter to isolate the filter for
changing the cartridge.
INSTALLATION PROCEDURE
1.
Isolate water supply and relieve pressure by opening a downstream tap.
2.
Cut pipe to suit length of required valve and housing installation.
3.
Use approved brass, galv/poly plumbing fittings to suit existing pipework. The female threads on the housing will receive
tapered male threads. Thread into housing head carefully as too much tape or overtightening may cause it to split.
Warning: Use PTFE thread seal tape on all connections. Use of pipe sealants will void warranty.
4.
If using sweated fittings, allow enough time to cool before connecting to the housing.
5.
Securely fix wall mount bracket and pipework with suitable clips. Allow 50mm clearance underbowl for filter changes.
6.
Flush debris from pipework.
7.
Install filter cartridge as per cartridge replacement instructions (pg.6).