Page - 57
DEFROST1 SENSOR SHORT
or
DEFROST2 SENSOR SHORT
ISSUE
Shorted defrost sensor.
RESOLUTION
A qualified technician should replace the defrost sensor.
ERROR AT MASTER UNIT
ISSUE
The heat pump is slaved to a master heat pump that is displaying a fault code.
RESOLUTION
The error at the master heat pump must be corrected before the slaved unit will resume operation.
HIGH PRESSURE FAULT
ISSUE
The refrigerant system’s high-pressure switch is showing as open.
RESOLUTION
Heat Only Units
Place heat pump in heating mode and perform the following troubleshooting.
Determine if an insufficient amount of water is being supplied to the equipment.
1. Confirm the filter pump is on.
2. If a multiple-speed filter pump is being used, run filter pump at a higher speed. Do not exceed the
maximum flow rate for the model.
3. Confirm water is not being diverted away from the heat pump.
l
l
Adjusting Water Flow Using ΔT (Delta-T)
4. The water pressure switch may be incorrectly calibrated.
l
Adjusting Water Pressure Switch
HIGH WATER TEMPERATURE
ISSUE
Incoming water temperature has exceeded 110° F (43° C) and the unit has been deactivated. The heat
pump will not operate until the incoming water temperature drops to 100° F (38° C) or lower.
RESOLUTION
1. Determine if a gas heater is sending water directly to the heat pump. This situation would need to be
corrected before continuing.
2. If a solar heater is sending water directly to the heat pump, the water can initially be hotter than 110° F
(43° C). After the water from the solar panel normalizes, the fault will no longer display and the heat pump
will resume as needed.
3. If the
HIGH WATER TEMPERATURE
fault continues to display, the water temperature sensor may
require replacement.
2
-
T
roubl
es
hoot
ing
Summary of Contents for Leisure Temp LT1000
Page 2: ......
Page 9: ...Page 6 1 3 Dimensions Leisure Temp LT55 Leisure Temp LT400 1 Installation...
Page 10: ...Page 7 Leisure Temp LT600 Leisure Temp LT700 LT800 1 Installation...
Page 26: ...Page 23 Configure Call Flex Enter Installer Menus then proceed 1 Installation...
Page 30: ...Page 27 1 Installation...
Page 33: ...Page 30 1 Installation...
Page 36: ...Page 33 Configure for 24 Hour Mode Enter Installer Menus then proceed 1 Installation...
Page 37: ...Page 34 Configure for Scheduled Mode Enter Installer Menus then proceed 1 Installation...
Page 38: ...Page 35 1 Installation...
Page 41: ...Page 38 1 Installation...
Page 43: ...Page 40 1 Installation...
Page 46: ...Page 43 1 Installation...
Page 50: ...Page 47 1 Installation...
Page 53: ...Page 50 1 Installation...
Page 55: ...Page 52 1 Installation...
Page 72: ......