Page - 6
WARNING - Failure to heed the following may result in
permanent injury or death.
l
RISK OF ELECTRICAL SHOCK - Disconnect all AC power
when installing or servicing this system. Follow all state, local,
and National Electrical Code (provincial and Canadian
Electrical Code(s) if applicable). Use copper conductors only.
l
RISK OF ELECTRICAL SHOCK - All electrical connections
should be made by a licensed electrician or certified electrical
contractor.
l
RISK OF ELECTRICAL SHOCK - Risk of electrical shock from
energy stored in capacitors - Models equipped with variable
frequency compressor drives store electricity even after the
power has been deactivated at the power breaker.
Wait for 2
minutes after the shut down of equipment before servicing.
l
RISK OF ELECTRICAL SHOCK - Only qualified professionals
who are familiar with the swimming pool and spa safety
standards should service this unit. The installer must be
familiar with service industry techniques.
AquaCal
®
Heat Pump Wiring
1. Turn off all power to the heat pump.
Wait for 2 minutes after
the shut down of equipment before removing panels.
2. Open the pool heater front cabinet to expose the electrical
access panel and control board.
3. Locate Port D on the HP9 control board. Confirm you have the
correct port by removing the four-pin connector. The port
identification will be printed on the PCB.
4. Connect the wires as per the diagram on the following page.
5. Verify the wires are firmly held in place by gently pulling on the
wire.
6. Replace the connector onto the PCB header pins. Be sure to
align correctly.
PoolSync
TM
Wiring
Figure 4