Status of the non-active signal (recirculation pump ON):
if the signal is identified as not active (
Lo
steady or flashing), or active but near the threshold(flashing
HI
),
press
▲
to increase the threshold voltage until a steady “
HI
” is displayed;
if the signal is permanently identified as not active (steady
HI
), conduct a check when the signal is
disabled;
Choose if you want to enable modification of the parameters from the online User Menu,
OnL
: to enter and
exit the submenu, use the
Enter
key, use the
▲
and
▼ keys to choose "YES/no";
Enable the
bu.E
buzzer when an alarm is activated: to enter and exit the submenu, use the
Enter
key, use
the
▲
and
▼ keys to choose "
YES/no
";
To go back to the Programming Menu, to the
Opt
entry, just press
Enter
for 3 seconds from any entry of the Menu.
Fig. 15 - Settings Menu
4.0 ALARMS
4.1 MAINTENANCE ALARM
The maintenance alarm is activated when the pump has been running for longer than the time set in the relevant
O.F.d
If you set 0.00 (h.mm) as a time value for the maintenance alarm, it will be disabled.
This is reported by the pump as follows:
Audio signal via the buzzer (if there is one on the pump) if enabled (see
bu.E
in the
) with a
frequency of 1 second on and 1 second off;
flashing red LED;
“
OFd
” flashing on the display;
In this alarm status the motor is stationary. To disable the alarm, you need to go to the
P.d.t
entry (pump operating
time) in the Statistics Menu and reset the value.
4.2 LEVEL ALARM (only for the model with the level probe)
An optional level probe can be connected to the pump to report the end of the product, which is indicated by the
pump in the following way:
Audio signal via the buzzer (if there is one on the pump) if enabled (see
bu.E
in the "
") with a
frequency of 1 second on and 1 second off;
flashing red LED;
“
uLo
” flashing on the display;
The inlet has a 3-second recognition filter to identify false contacts and unwanted level alarm signals.