Simpool Pool-T Model
INSTRUCTION AND MAINTENANCE MANUAL
Programmable digital peristaltic pump
ENGLISH
ADSP7000642
rev. 1.0
13/01/2014
48/72
You can browse through the User Menu with the
F
key and display, depending on the set modes:
Prl
: allows to prime the pump without using the switch. You can start or stop the priming with the
Enter
key. The display shows a flashing “
Prl
” and the pump starts running at top speed.
Timed dosing cycle mode
t.rI:
duration of the Delay Phase, that can be set from 0 to 999 seconds;
t.do:
duration of the Dosing Phase, that can be set from 1 to 99 minutes;
bL.t:
duration of the Block Phase, that can be set from 0 to 99 minutes;
Quantity dosing cycle mode
t.rI:
duration of the Delay Phase, that can be set from 0 to 999 seconds;
G.nC:
g/cu. m. of product, that can be selected from 0.0 to 99.9, and from 100 to 999;
dEn:
density of the product in g/l , displayed as the difference from the value of 1000 g/ l, from -50 to 500
g/l, i.e. in the density range of 950- 1500 g/l;
bL.t:
duration of the Block Phase, that can be set from 0 to 99 minutes;
It will be possible to modify the parameters only in case they have been enabled from the Settings Menu, i.e.:
OnL
(On-line change) enabled;
From the User Menu you can go back to the Initial Menu by pressing the
F
key for 3 seconds.
If there are one or several active alarms, every page of the Initial Menu and of the User Menu will be
alternated to the entry that reports the alarm with the top priority.
Programming Menu
The Programming Menu allows to set all of the pump operating parameters and can be accessed only by entering
the password.
The Programming Menu can be accessed only using the Initial Menu: after pressing
Enter
for 3 seconds, the
display s
hows “
PAS
”, the LED turns orange and is steady. Then press
Enter
again and on the password selection
menu the first digit of “
000
” starts flashing. With the
▲
and
▼ keys you can increase/decrease the value displayed,
with
Enter
you can scroll and select the desired digit. After setting the correct password, press
Enter
again for 3
seconds.
3.2 QUICK START-UP
This section features the steps to carry out to use the pump straight away. For further details on operation, refer to
section 3.3 "Advanced Programming".
3.2.1 QUICK START-UP - Timed Dosing Cycle Mode
These are the fundamental parameters to be set to activate the pump:
Delay Time
–
Dosing Time
–
Block Time
From the User Menu you can proceed quickly with the steps below:
Prime the pump;
Delay time setting;
Dosing time setting;
Block time setting;
Here below are the pump default parameters:
No Repeat Mode;
On-line Change from User Menu values enabled;
Stabilization Time of the Inhibitory Signal: 10 sec.;