background image

100 Series Maxi Internal Filters  

Summary of Contents for 101F

Page 1: ...100 Series Maxi Internal Filters ...

Page 2: ... wet do not unplug the appliance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the socket 5 Always unplug the appliance from the electrical outlet when not in use before putting on or taking off parts before any type of maintenance or cleaning 6 Never yank the cable to pull it from the socket Pull the plug carefully...

Page 3: ...at guarantee service is required Carefully unpack the product making sure you keep all the packing material until all the parts of the product have been found and the product has been assembled Correct Positioning in Aquarium Set the filter up within the arrows indicated above Filter must not be out of the water and must not be in contact with any substrate This product is shipped to you in a fact...

Page 4: ...cated on the product 101F Maxi Sponge 25S 101F Maxi Impeller 1I 102F Maxi Sponge 26S 102F Maxi Impeller 26I Know Your Filter 101F 102F 1 Motor 2 Impeller 3 Impeller Cover 4 Sponge 5 Top Sponge Casing 6 Sponge 102F Only 7 Bottom Sponge Casing 102F Only 8 Spray bar outlet 9 Elbow 10 Spray Bar 11 Duck Bill Outlet 12 13mm Outlet 13 9mm Outlet 14 Venturi Outlet 15 Venturi Air Line Aqua One Spare Parts ...

Page 5: ... Decide on which outlet option to use a If no attachment is required simply push the direct outlet or reducer into pump outlet b If the venturi is required push venturi outlet directly into pump outlet hang airline outside of your aquarium c If the duckbill is to be used push duckbill outlet directly into pump 2 Suction cups will fasten the filter to the wall of you aquarium It is best to have sur...

Page 6: ...em This will help keep your filter working better Accessing The Impeller Clean the impeller at least once a month 1 Grasp the motor with one hand and filter casing with the other and gently pull apart 2 Remove the impeller cover to gain access to the impeller 3 Pull impeller from the motor and rinse properly Use an Aqua One double ended pipe brush to clean the impeller and the impeller well and al...

Page 7: ... Bar 16 Venturi Air Line 17 Venturi Outlet 18 16mm Outlet Aqua One Spare Parts 28I Replacement Parts Filter Media Use Aqua One Genuine Spare Parts Only See your local Aqua One Dealer and look for the number listed below for the spare part you require Alternatively you will find these numbers on the silver label located on the product 103F Maxi Sponge 27S 103F Maxi Impeller 27I 104F Maxi Sponge 28S...

Page 8: ...utlet option to use a If no attachment is required simply push the direct outlet into pump outlet b If the venturi is required push venturi outlet directly into pump outlet hang airline outside your aquarium 2 Suction cups will fasten the filter to the wall of you aquarium It is best to have surface agitation if it is being used as the sole filter 3 Use flow adjuster on the front of the filter wil...

Page 9: ...h it in tap water Only wash one sponge at a time and rotate them This will help keep your filter working better Accessing The Impeller Clean the impeller at least once a month 1 Follow step 2 in the maintenance section to gain access to the impeller cover 2 Turn the impeller cover anti clock wise to gain access to the impeller 3 Pull impeller from the motor and rinse properly Use an Aqua One doubl...

Page 10: ...hat the product must not be disposed of with normal household waste Instead it is your responsibility to dispose of your waste equipment by arranging to return it to a designated collection point for the recycling of waste electrical and electronic equipment By separating and recycling your waste equipment at the time of disposal you will help to conserve natural resources and ensure that the equi...

Page 11: ...he original manufacturer s guarantee period 5 Guarantee does not cover a Cost of freight postage or the cost of insurance b Service costs arising from failure to correctly adjust the controls of the product or to clean the hoses filter media impellers pump heads failure to observe the manufacturer s instructions or inspections that reveal that the equipment is in normal working order c Equipment f...

Page 12: ...12 www aquaone com au Aqua One is a registered trademark ...

Reviews: