background image

Please read the operation instructions carefully before using this product.

Operation Instructions

AQUA MARINA

ELECTRIC PUMP

(Max. Air Pressure 20PSI)

Summary of Contents for B0302944

Page 1: ...Please read the operation instructions carefully before using this product Operation Instructions AQUA MARINA ELECTRIC PUMP Max Air Pressure 20PSI ...

Page 2: ...Index 2 I Content List 3 II Overview 3 III Safety Instructions 4 IV Inflation Operation 5 V Deflation Operation 6 VI Precautions 6 VII Trouble Shooting 7 VIII Maintenance and Storage 7 IX Warranty 8 ...

Page 3: ...act the local dealer for after service Air Pump Hose Battery Clamp User Manual Inflation inlet Deflation outlet DC plug LCD screen PSI BAR toggle button Up button Down button On off button Hose Air nozzle Flexible conduit adaptor Battery clamp II Overview 4 3 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 1 2 11 10 9 20 00 3 12 ...

Page 4: ...g If you are standing in a place with water or your hands are wet please don t operate the power plug Warning Check the maximum air pressure of the inflatable product before inflating The air bag can be damaged by exceeding the Max air pressure Warning Check the cigarette lighter socket before use to ensure that there is no rust or residue inside The poorly conductive cigarette lighter socket may ...

Page 5: ...o 20PSI 1PSI 0 0689BAR After finishing the above steps press the On Off button to start inflation During the inflating process you can press the UP button or DOWN button to increase or decrease the targeted air pressure press the toggle button to switch the unit of air pressure and press the On Off button to stop Long press the On Off button for 3 seconds to start inflation directly When the air p...

Page 6: ...erheating may cause internal damage The air pump shall be fully cooled for 30 mins after continuously working up to 20 mins Notice The factory default setting air pressure is 10PSI 10PSI 0 689BAR From the second time use the default air pressure will be the value you set in last time Notice When the air pump is powered on and without any operation over 2 minutes it will enter standby mode You can ...

Page 7: ...Do not drop or violently shake the pump 7 VII Trouble Shooting VIII Maintenance and Storage Fault Inspection Solution The air pump cannot be started normally 1 The power source is not plugged properly 2 The fuse in DC plug is burnt out 3 Overheating or overload causes motor stop 1 Make sure that the power wire is plugged in the 12VDC socket 2 Change the fuse 3 Cool the motor and restart it 4 If th...

Page 8: ...re damage caused by improper handling and storage or damage caused by anything other than defects in material and workmanship 4 This warranty is void if any unauthorized repair change or modification has been made to any part of the equipment 5 The warranty for any repaired or replacement equipment is good from the date of the original purchase only 6 The original purchase receipt must accompany a...

Reviews: