Installation and Maintenance Manual 

For 

Delta Star Water-cooled Marine Duty  

In-Line Water Heat Pumps 

(Models DSHP-4-WCMD thru DSHP-10-WCMD) 

 
 
 

 

 
 

DSHP-9-WCMD shown 

 

Use Quick Install page for easy setup

.

 

 
 
 
 
 
 

Aqua Logic, Inc. 

9558 Camino Ruiz. 

San Diego, CA 92126 

PH: 858.292.4773   Fax: 858.292.0537 

Email: [email protected]  

Website: www.aqualogicinc.com 

 
 
 

Summary of Contents for DSHP-10-WCMD

Page 1: ...______ Installation and Maintenance Manual For Delta Star Water cooled Marine Duty In Line Water Heat Pumps Models DSHP 4 WCMD thru DSHP 10 WCMD DSHP 9 WCMD shown Use Quick Install page for easy setup...

Page 2: ...mium quality components to assemble equipment that will operate faithfully for years You can call us or visit us on the web for technical assistance before and after the sale We are committed to makin...

Page 3: ...or repair if necessary Be sure that the water flow through your Aqua Logic Heat Pump goes into the water inlet bottom and out the top to prevent potential damage see illustration If you use flexible h...

Page 4: ...fittings for leaks Apply electrical power to the Heat Pump Adjust the controller to the desired water temperature See Operation and Programming Important Regulate condenser water until pressure on th...

Page 5: ...ss either up key to increase or the down key to select the correct Stage 1 mode Stage 1 MUST be in the H1 mode for correct operation 5 Press the SET key again to access the chill mode set point temper...

Page 6: ...a temperature controller on the lights to shut them off and to sound off an alarm if water temperature rises more than 5 F above the Heat Pump set point Keep a spare pump on hand in case your primary...

Page 7: ...sure to wear appropriate protective gear Use extreme caution when using caustic chemicals around your system To remove accumulated organics slime Remove power from the Heat Pump Wear protective eyewea...

Page 8: ...hes Weight lbs DSHP 4 WCMD 1 3 4050 115 7 2 R 134A 10 20 3 5 23 x 14 x 14 75 DSHP 5 WCMD 1 2 6000 115 9 5 R 134A 12 25 3 5 1 1 24 x 16 x 16 125 DSHP 6 WCMD 1 2 6000 230 4 8 R 134A 12 25 3 5 1 1 24 x 1...

Page 9: ...ation or maintenance by user or their agent Damage caused due to misapplication of product Damage caused by corrosion abuse accident alteration or improper use Damage caused by flood fire earthquake t...