15
2.
Leakage detection notice and method
a.
Leakage checking is prohibited in closed area.
b.
The ignition source is prohibited during the leakage inspection. A halide torch (or any
other detector using a naked flame) shall not be used.
c.
Leakage detection fluids can be applied with most refrigerants but the use of detergents containing
chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper
pipe.
d.
Vacuumize completely before welding. Welding can only be carried out by professional personnel
in service center.
e.
Please stop using while gas leakage occur, and contact professional personnel in service center.
3.
Trial
a.
The user must “Start the Pump before the Machine, and Turn off the Machine before the Pump”, or
the machine will be damaged.
b.
Before start the heat pump, please check for any leakage of water; and set suitable temperature in
the thermostat, and then switch on power supply.
c.
In order to protect the swimming pool heat pump, the machine is equipped with a time lag starting
function, the fan will run 1 minute earlier than the compressor when starting the machine, and it will
stop running 1 minute later than the compressor when power off the machine.
d.
After the swimming pool heat pump start up, please kindly checking for any abnormal noise from the
machine.