APW Wyott SM-50-11DS Owner'S Manual Download Page 1

BUILT-IN ROUND WELL WARMERS WITH 

THERMOSTAT CONTROL

(Insulated & Non-Insulated)

MODELS:

SM-50-4ULS, SM-50-4DULS, SM-50-7DS, SM-50-7ULS,

SM-50-7DULS, SM-50-11S, SM-50-11DS, SM-50 11DULS

OWNERS MANUAL

2M-Z24236  REV A (03-22)

is a registered trademark of APW Wyott®, A Middleby Company.  All rights reserved.

This manual includes material related to installation, use , cleaning, and care. Exploded view[s], as well as any available 

parts list[s] and wiring diagram[s] pertaining to the unit[s] covered by this manual are also included.
This manual must be read and understood by all persons using or installing this appliance. Contact your APW Wyott 

dealer if you have any questions concerning installation, use, or maintenance of this equipment.
DO NOT DISCARD THIS MANUAL.

Summary of Contents for SM-50-11DS

Page 1: ...l rights reserved This manual includes material related to installation use cleaning and care Exploded view s as well as any available parts list s and wiring diagram s pertaining to the unit s covere...

Page 2: ...iness Hours 8 00 a m to 4 30 p m Central Telephone 800 264 7827 Tech Service Option 2 Email TechService partstown com www apwwyott com WARRANTY EXCLUSIONS THE FOLLOWING WILL NOT BE COVERED UNDER WARRA...

Page 3: ...asing this APW Wyott appliance Proper installation professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long economical ser...

Page 4: ...ial position is an indication of the temperature setting Actual temperature will vary depending upon the type of product and food consistency B MOUNTING 1 Top mounted built in warmers are be equipped...

Page 5: ...er use is recommended or authorized by the manufacturer or its agents Operators of this appliance must be familiar with the appliance use limitations and associated restrictions Operating instructions...

Page 6: ...s before discarding packing materials Store all accessories in a convenient place for later use INSTALLATION NOTES 1 Installation and start up of built in warmers MUST be performed by an authorized in...

Page 7: ...ably decreased performance 2 Available electrical service amperage must meet or exceed the specifications listed on the specification sheet provided with the warmer 3 Warmer and control unit must be c...

Page 8: ...not supplied by APW Wyott to be installed in order to operate correctly 5 For AUTOFILL units Some jurisdictions may require an approved back flow preventer in the water supply line It is the responsi...

Page 9: ...e adding water 4 Damage caused by allowing a wet operation warmer to run dry is NOT covered by warranty Damage caused by adding water to a dry warmer when hot is NOT covered by warranty PRE HEATING TH...

Page 10: ...ill lower the temperature of the food in the insert pan and may damage the warmer 3 Alternating between wet and dry operation in any individual warmer is NOT recommended 4 DO NOT use metal tools steel...

Page 11: ...pans insets and other vessels are subject to a harsher environment APW Wyott Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainless...

Page 12: ...etergent cleanser residue 4 Inspect warmer flange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insulation and heating e...

Page 13: ...overs accumulated scale 2 Heat water to maximum temperature 190 F or higher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control...

Page 14: ...yott Service Agency for repairs Warmer slow to heat Mineral deposits on pan acting as a insulator Clean pan s with delime cleaner Wired to wrong voltage Verify supply voltage must match voltage on war...

Page 15: ...2M Z24236 Owners Manual for Built In Round T Stat Warmers 13 WIRING DIAGRAM...

Page 16: ...rmers 14 EXPLODED VIEW PARTS LIST SM 50 7S and SM 50 11S with without Drain IL1904 Rev F 4 08 15 Model SM 50 4S SM 50 7S SM 50 11S w w o Drain SM 50 4ULS SM 50 7ULS SM 50 11ULS w w o Drain 1 2 22 3 4...

Page 17: ...CONDUIT UNITS 11 WS 60282 THERMO CONTROL 1 SM 50 4S SM 50 4DS SM 50 7S SM 50 7DS SM 50 11S 12 P2 40843 THERMOSTAT MOUNTING BRKT 1 13 I7 Z12221 CONTROL PANEL 1 14 2J 35687 LIGHT SIGNAL 1 15 2R Z24181 C...

Page 18: ...T w hinged lid 21057 E Z Lock EXTENSION KIT for UL LISTED circular warmers only adapt to wood counter up to 1 thick 22592 E Z Lock Extension Kits for UL Listed units approved for installation in wood...

Page 19: ...2M Z24236 Owners Manual for Built In Round T Stat Warmers 17 NOTES...

Page 20: ...65 Hobson St Smithville TN 37166 Telephone 800 527 2100 Printed in the U S A 2M Z24236 REV A 03 22 Specifications are subject to change without notice is a registered trademark of APW Wyott A Middleby...