APT VEYRON E 8KW User Manual Download Page 1

 

 

 
 
 

 
 
 
 

VEYRON E 8KW 

SOLAR INVERTER / CHARGER

 

 
 
 
 

 
 
 
 

 

Version: 1.0 

User Manual 

Summary of Contents for VEYRON E 8KW

Page 1: ...VEYRON E 8KW SOLAR INVERTER CHARGER Version 1 0 User Manual...

Page 2: ...3 Operation and Display Panel 13 LCD Display Icons 14 LCD Setting 17 LCD Display 32 Operating Mode Description 38 Faults Reference Code 43 Warning Indicator 44 CLEARANCE AND MAINTENANCE FOR ANTI DUST...

Page 3: ...rectly operate this inverter charger 8 Be very cautious when working with metal tools on or around batteries A potential risk exists to drop a tool to spark or short circuit batteries or other electri...

Page 4: ...LCD control panel Configurable AC PV output usage timer and prioritization Configurable AC Solar charger priority via LCD control panel Configurable battery charging current based on applications via...

Page 5: ...ion keys 4 PV connectors 5 AC input connectors 6 AC output connectors Load connection 7 Battery connectors 8 Circuit breaker 9 Dry contact 10 USB port as USB communication port and USB function port 1...

Page 6: ...remove one cables as shown below Mounting the Unit Consider the following points before selecting where to install Do not mount the inverter on flammable construction materials Mount on a solid surfa...

Page 7: ...ropriate cable for battery connection To reduce risk of injury please use the proper recommended cable and terminal size as below Recommended battery cable and terminal size Model Typical Amperage Bat...

Page 8: ...d OUT markings Please do NOT mis connect input and output connectors WARNING All wiring must be performed by a qualified personnel WARNING It s very important for system safety and efficient operation...

Page 9: ...es such as air conditioner requires at least 2 3 minutes to restart because it s required to have enough time to balance refrigerant gas inside of circuits If a power shortage occurs and recovers in a...

Page 10: ...male terminal and crimp male terminal as shown below Insert assembled cable into male connector housing as shown below Then use spanner to screw pressure dome tightly to female connector and male conn...

Page 11: ...Array Power Q ty of modules Wp 555Wp Min in series 3pcs per input Vmp 32 06Vdc Max in series 8pcs per input Imp 17 32A 3pcs in series x 3pcs 1665W Voc 38 46Vdc x 3pcs in series 3pcs 1665W Isc 18 33A 3...

Page 12: ...to the software user manual on the bundled CD Wireless Connection There is switch button located on the bottom case You may select WiFi or Bulutooth with this switch button WiFi Connection This unit...

Page 13: ...uipped with a Bluetooth transmitter Download WatchPower APP from Google Play or Google Store Once the APP is download you may connect WatchPower APP to your inverter with the password 123456 The commu...

Page 14: ...utility first or SUB solar first Battery voltage Low DC warning voltage Open Close Battery voltage Setting value in Program 13 or battery charging reaches floating stage Close Open Program 01 is set...

Page 15: ...ply press On Off switch located on the side of the inverter to turn on the unit Operation and Display Panel The operation and the LCD module shown in the chart below includes six indicators six functi...

Page 16: ...y Constant Current mode Constant Voltage mode 2V cell 4 bars will flash in turns 2 2 083V cell The right bar will be on and the other three bars will flash in turns 2 083 2 167V cell The right two bar...

Page 17: ...am 16 Charger source priority is selected as Solar only Output source priority setting display Indicates setting program 01 Output source priority is selected as Utility first Indicates setting progra...

Page 18: ...ts to the mains Indicates unit connects to the PV panel Indicates battery type Indicates parallel operation is working Indicates unit alarm is disabled Indicates Wi Fi transmission is working Indicate...

Page 19: ...energy provides power to the loads as first priority If solar energy is not sufficient to power all connected loads Utility energy will supply power to the loads at the same time SBU priority Solar e...

Page 20: ...e AGM default Flooded User Defined If User Defined is selected battery charge voltage and low DC cut off voltage can be set up in program 26 27 and 29 Pylontech battery If selected programs of 02 26 2...

Page 21: ...atically set up No need for further setting 3rd party Lithium battery If selected programs of 02 26 27 and 29 will be automatically set up No need for further setting Please contact the battery suppli...

Page 22: ...charger 30A default Setting range is from 2A then 10A to 120A Increment of each click is 10A 12 Setting voltage point back to utility source when selecting SBU SBU priority in program 01 46V default...

Page 23: ...d utility will charge battery at the same time Only Solar Solar energy will be the only charger source no matter utility is available or not 18 Alarm control Alarm on default Alarm off 19 Auto return...

Page 24: ...ge C V voltage 56 4V default If user defined is selected in program 5 this program can be set up Setting range is from 48 0V to 62 0V Increment of each click is 0 1V 27 Floating charging voltage 54V d...

Page 25: ...rgy battery power and utility are all available inverter will transfer to line mode and provide output power to loads 42 0V default If user defined is selected in program 5 this program can be set up...

Page 26: ...ange is from 0 to 90 days Increment of each click is 1 day 36 Equalization activated immediately Enable Disable default If equalization function is enabled in program 30 this program can be set up If...

Page 27: ...nt of each click is 10A If discharging current is higher than setting value battery will stop discharging At this time if the utility is available the inverter will operate in bypass mode If no utilit...

Page 28: ...is from 0 to 23 87 Time setting Day For day setting the range is from 1 to 31 88 Time setting Month For month setting the range is from 1 to 12 89 Time setting Year For year setting the range is from...

Page 29: ...default High 93 Lighting speed of RGB LED Low Normal default High 94 RGB LED effects Power cycling Power wheel Power chasing Solid on Default 95 Data Presentation of data color Solar input power in wa...

Page 30: ...28 Load percentage 96 Background color of RGB LED Pink Orange Yellow Green Blue Sky blue Default Purple Other 97 Data Color for RGB LED Pink Orange Yellow Green...

Page 31: ...r output source priority and timer setting for charger source priority Procedure LCD Screen Step 2 Insert an OTG USB disk into the USB port Press button to enter USB Setup Mode detail descriptions in...

Page 32: ...n to confirm the selection again Press button to select Yes LED 1 will flash once every second during the process It will only display and all LEDs will be on after this action is complete Then press...

Page 33: ...etting for the Charger Source Priority This timer setting is to set up the charger source priority per day Procedure LCD Screen Step 1 Press or button to enter the selectable programs detail descripti...

Page 34: ...nformation LCD display Default Display Screen Utility voltage Utility frequency Utility current switch every 5 second Input Voltage 230V Input frequency 50Hz Input Voltage 230V Input current 4 8A If s...

Page 35: ...V2 power 600W Battery voltage charging stage Configured battery parameters Charging or discharging current Battery voltage 50 4V Bulk charging voltage 56 4V Charging current 20A Battery voltage 53 9V...

Page 36: ...put voltage load in VA load in Watt switch every 5 second Output frequency Output voltage 230V Output frequency 50Hz Load in VA 2 4kVA Output frequency 50Hz Load in Watt 2 4kW Output frequency 50Hz Re...

Page 37: ...Real time 11 38 PV energy generated today PV energy generated today 888Wh PV energy generated this month PV energy generated this month 8 88kWh PV energy generated this year PV energy generated this...

Page 38: ...rgy generated Total PV energy generated 888kWh Load output energy today Load energy today 888Wh Load output energy this month Load energy this month 8 88kWh Load output energy this year Load energy th...

Page 39: ...put energy Total load output energy 888kWh Main CPU version checking Main CPU version 00050 72 Secondary CPU version checking Secondary CPU version 00022 01 Bluetooth Wi Fi version checking BLE Wi Fi...

Page 40: ...turned on yet but at this time the inverter can charge battery without AC output No output is supplied by the unit but it still can charge batteries Charging by utility and PV energy Charging by utili...

Page 41: ...mode Note Fault mode Errors are caused by inside circuit error or external reasons such as over temperature output short circuited and so on PV energy and utility can charge batteries Charging by uti...

Page 42: ...ty If SUB solar first is selected as output source priority and solar energy is not sufficient to provide the load solar energy and the utility will provide the loads and charge the battery at the sam...

Page 43: ...ains It will also charge the battery at line mode Power from utility Power is only generated from PV energy and feeds PV energy to grid when battery is not connected PV energy charges battery provides...

Page 44: ...ovide output power from battery and or PV power Power from battery and PV energy PV energy will supply power to the loads and charge battery at the same time No utility is available Power from battery...

Page 45: ...Output short circuited 06 Output voltage is too high 07 Overload time out 08 Bus voltage is too high 09 Bus soft start failed 10 PV over current 11 PV over voltage 12 DCDC over current 13 Battery dis...

Page 46: ...Battery is over charged Beep once every second 04 Low battery Beep once every second 07 Overload Beep once every 0 5 second 10 Output power derating Beep twice every 3 seconds 15 PV energy is low Beep...

Page 47: ...keeps dusk from your inverter and increases product reliability in harsh environment Clearance and Maintenance Step 1 Please remove the screw on the two sides of the inverter Step 2 Then dustproof ca...

Page 48: ...float stage when the setting equalization interval battery equalization cycle is arrived or equalization is active immediately the controller will start to enter Equalize stage Equalize charging time...

Page 49: ...x AC Input Current 60A Nominal Input Frequency 50Hz 60Hz Auto detection Low Loss Frequency 40 1Hz Low Loss Return Frequency 42 1Hz High Loss Frequency 65 1Hz High Loss Return Frequency 63 1Hz Output S...

Page 50: ...Capacity 2 rated power for 5 seconds Low DC Warning Voltage 46 0Vdc 42 8Vdc 40 4Vdc load 20 20 load 50 load 50 Low DC Warning Return Voltage 48 0Vdc 44 8Vdc 42 4Vdc load 20 20 load 50 load 50 Low DC C...

Page 51: ...arging Algorithm 3 Step Charging Curve Time Battery Voltage per cell Charging Current 100 50 Bulk Constant Current Absorption Constant Voltage Maintenance Floating Current Voltage minimum 10mins maxim...

Page 52: ...n condensing Dimension D W H mm 147 4x 432 5 x 553 6 Net Weight kg 18 4 Table 5 Parallel Specifications MODEL 8KW Max parallel numbers 6 Circulation Current under No Load Condition Max 2A Power Unbala...

Page 53: ...s switched on and off repeatedly LCD display and LEDs are flashing Battery is disconnected Check if battery wires are connected well Buzzer beeps continuously and red LED is on Fault code 07 Overload...

Page 54: ...Ring Terminal Torque value Dimensions D mm L mm 1 2 0AWG 67 4 8 4 47 5 Nm WARNING Be sure the length of all battery cables is the same Otherwise there will be voltage difference between inverter and b...

Page 55: ...60A 230VAC Note 1 Also you can use 60A breaker with only 1 unit and install one breaker at its AC input in each inverter Note 2 Regarding three phase system you can use 4 pole breaker directly and the...

Page 56: ...54 Three inverters in parallel Power Connection Communication Connection 2 1 3 Four inverters in parallel Power Connection Communication Connection 2 1 3 4...

Page 57: ...55 Five inverters in parallel Power Connection Communication Connection 2 1 3 4 5 Six inverters in parallel Power Connection Communication Connection 2 1 3 4 5 6...

Page 58: ...ment Two inverters in each phase Power Connection Communication Connection 2 1 3 4 5 6 P1 P2 P3 Four inverters in one phase and one inverter for the other two phases Power Connection Communication Con...

Page 59: ...cond phase and one inverter for the third phase Power Connection Communication Connection 2 1 3 4 5 6 P1 P3 P2 Three inverters in one phase and only one inverter for the remaining two phases Power Con...

Page 60: ...the remaining phase Power Connection Communication Connection 2 1 3 4 5 P1 P3 P2 Two inverters in one phase and only one inverter for the remaining phases Power Connection Communication Connection 2 1...

Page 61: ...nnect the current sharing cable between the inverters which are in different phases Otherwise it may damage the inverters 5 PV Connection Please refer to user manual of single unit for PV Connection C...

Page 62: ...rated in 3 phase application please choose 3PX to define each inverter It is required to have at least 3 inverters or maximum 6 inverters to support three phase equipment It s required to have at leas...

Page 63: ...Unidentified unit master or slave HS Master unit SL Slave unit 7 Commissioning Parallel in single phase Step 1 Check the following requirements before commissioning Correct wire connection Ensure all...

Page 64: ...as P1 P2 and P3 sequentially And then shut down all units NOET It s necessary to turn off switch when setting LCD program Otherwise the setting cannot be programmed Step 3 Turn on all units sequential...

Page 65: ...oss 83 The battery voltage of each inverter is not the same 1 Make sure all inverters share same groups of batteries together 2 Remove all loads and disconnect AC input and PV input Then check battery...

Page 66: ...cal ID to each battery module for normal operation We can set up the ID code for each battery module by rotating the PIN number on the ID switch From number 0 to 9 the number can be random no particul...

Page 67: ...It s required to set up master battery on the third group with this setting and slave batteries are unrestricted 0 0 1 Multiple group condition It s required to set up master battery on the fourth gro...

Page 68: ...on for 5 secs in the front panel the battery will start up Step 3 Press more than three seconds to start Lithium battery power output ready Step 4 Turn on the inverter Step 5 Be sure to select battery...

Page 69: ...tep 2 Switch on Lithium battery Step 3 Press more than three seconds to start Lithium battery power output ready Step 4 Turn on the inverter Step 5 Be sure to select battery type as PYL in LCD program...

Page 70: ...in LCD program 5 The remaining inverters are set as USE Step 2 Switch on Lithium battery Step 3 Turn on the inverter Step 4 Be sure to select battery type as WEC in LCD program 5 If communication bet...

Page 71: ...ery type of this inverter to SOL in LCD program 5 The remaining inverters are set as USE Step 2 Open DC isolator and switch on Lithium battery Step 3 Turn on the inverter Step 4 Be sure to select batt...

Page 72: ...ation between the inverter and battery is successful it will show code 60 to stop charging and discharging battery Communication lost only available when the battery type is not setting as AGM Flooded...

Page 73: ...ccurs Allows users to query inverter history data 2 WatchPower App 2 1 Download and install APP Please scan the following QR code with your smart phone and download WatchPower App Android system iOS s...

Page 74: ...Wi Fi Config page There are detailed setup procedure listed in How to connect section and you may follow it to connect Wi Fi Enter the Settings Wi Fi and select connected Wi Fi name The connected Wi F...

Page 75: ...Fi module and the Internet If the connection fails please repeat Step 2 and 3 Diagnose Function If the module is not monitoring properly please tap on the top right corner of the screen for further de...

Page 76: ...ed name and password to login Note Tick Remember Me for your login convenience afterwards Overview After login is successfully you can access Overview page to have overview of your monitoring devices...

Page 77: ...r to add device This part number label is pasted on the bottom of remote LCD panel After entering part number tap Confirm to add this device in the Device list For more information about Device List p...

Page 78: ...en there is a dynamic power flow chart to show live operation It contains five icons to present PV power inverter load utility and battery Based on your inverter model status there will be Standby Mod...

Page 79: ...nfirm to complete name modification Device Information Data Users can check up Basic Information Product Information Rated information History and Wi Fi Module Information by swiping left Basic Inform...

Page 80: ...ctly in the column Each function setting is saved by clicking Set button Please refer to below parameter setting list for an overall description and be noted that the available parameters may vary dep...

Page 81: ...e Disable Functions LCD Auto return to Main screen If enable LCD screen will return to its main screen after one minute automatically Fault Code Record If enabled fault code will be recorded in the in...