1. Introduction 

INVEREX Inverter is a compact inverter designed to power your home appliances or precious electronics. Its 
compact size features easy installation and high movability. Besides, its high surge capability also can handle 
motor-type loads such as vacuums, small freezers, or drills.   
 
Compared to traditional inverters in the market, this inverter provides two operation modes: UPS mode and 
Inverter mode. At UPS mode, the inverter becomes an UPS which can provide pure power source to PC-related 
equipment or sensitive devices. At Inverter mode, the inverter can provide continuous power to general home 
appliances. 

 

2. Important Safety Warning (SAVE THESE INSTRUCTIONS) 

Before using the inverter, please read all instructions and cautionary markings on the unit, this 
manual and the batteries. 
 

 

 

General Precaution- 
CAUTION!

 The unit is designed for indoor use. Do not expose this unit to rain, snow or liquids of any type. 

CAUTION! 

To reduce risk of injury, only use qualified batteries from qualified distributors or manufacturers. 

Any unqualified batteries may cause damage and injury. Do NOT use old or overdue batteries. Please check the 
battery type and date code before installation to avoid damage and injury. 

WARNING! 

It's very important for system safety and efficient operation to use appropriate external battery 

cable. To reduce risk of injury, external battery cables should be UL certified and rated for 75°C or higher. And 
do not use copper cables less than 10AWG. Below is the external battery cable reference according to system 
requirements. 

 

CAUTION! 

Do not disassemble the inverter. Contact with the qualified service center when service or repair is 

required. 

WARNING! 

Provide ventilation to outdoors from the battery compartment. The battery enclosure should be 

designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment. 

CAUTION!

 Use insulated tools to reduce the chance of short-circuit when installing or working with the inverter, 

the batteries, or other equipments attached to this unit.   

CAUTION! 

For battery installation and maintenance, read the battery manufacturer's installation and 

maintenance instructions prior to operating. 

 
Personnel Precaution -   

CAUTION! 

Careful to reduce the risk or dropping a metal tool on the batteries. It could spark or short circuit the 

batteries and could cause an explosion. 

CAUTION!

 Remove personal metal items such as rings, bracelets, necklaces, and watches when working with 

batteries. Batteries can produce a short circuit current high enough to make metal melt, and could cause severe 
burns. 

CAUTION! 

Avoid touching eyes while working near batteries. 

CAUTION!

 Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes. 

CAUTION! 

NEVER smoke or allow a spark or flame in vicinity of a battery. 

CAUTION! 

If a remote or automatic generator start system is used, disable the automatic starting circuit or 

disconnect the generator to prevent accident during servicing.

 

 

 

Conventions used: 
WARNING! 

Warnings identify conditions or practices that could result in personal injury;   

CAUTION!   

Caution identify conditions or practices that could result in damaged to the unit or other 

equipment connected. 

Summary of Contents for Inverex XP Pro 1200

Page 1: ...Inverex Inverter V 1 0 Quick Guide...

Page 2: ...Table of Contents 1 Introduction 1 2 Important Safety Warning SAVE THESE INSTRUCTIONS 1 3 Product Overview 2 4 Installation 2 5 Operation 3 6 Trouble Shooting 8 7 Specifications 8...

Page 3: ...y cable reference according to system requirements CAUTION Do not disassemble the inverter Contact with the qualified service center when service or repair is required WARNING Provide ventilation to o...

Page 4: ...the battery terminal RED cable to the positive terminal BLACK cable to the negative terminal WARNING Please use the appropriate battery cable Please refer to Important Safety Warnings Section for the...

Page 5: ...alled press the power switch to turn on the unit The unit will work automatically in line mode or inverter mode according to input utility power s status When press the power switch again the unit wil...

Page 6: ...Voltage mode 11Vdc pcs 4 bars will flash in turns 11Vdc 11 5Vdc pcs Bottom bar will be on and the other three bars will flash in turns 11 5Vdc 12 5Vdc pcs Bottom two bars will be on and the other two...

Page 7: ...efined If User Defined is selected battery charge voltage and low DC cut off voltage can be set up in program 04 05 and 06 03 Max AC charging current 10A 20A default 04 Bulk charging voltage C V volta...

Page 8: ...age will be fixed to setting value no matter what percentage of load is connected Display Setting The LCD display information will be switched in turns by pressing SCROLL key The selectable informatio...

Page 9: ...utility Line Mode The unit will provide output power from the mains It will also charge the battery at line mode Charging by utility Battery Mode The unit will provide output power from battery Fault...

Page 10: ...the external battery cable and terminal Make sure all the battery connections to the unit are all correct Battery defect Replace the batteries Buzzer beeps continuously and red LED is on Fault code 00...

Reviews: