APsystems YC500i Series Installation & User Manual Download Page 14

YC500I Installation/User Manual

13

Installation Procedures

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

17

16

18

19

20

22

21

APsystems Microinverter&Energy Communication Unit

Warranty Card

The APsystems Installation Map is a diagram of the physical location of each microinverter in your  PV installation. 
Each APsystems microinverter has a removable serial number label located on the mounting plate. Pee l the label 
and affix it to the respective location on the APsystems installation map.
Installation Map Template

To register your APsystems microinverter, please mail this warranty registration card to: 

emasupport@altenergy-power com

.

B A B A

B A

Figure 12

NOTE:

1. The layout of the inverters' serial numbers on the warranty

card is only suitable for general arrangement.

2. Step 1~7 can be done in any order..
3. Warranty card is located in Appendix last page of this manual.

4. You can use Scanning Gun or mobile phone to scan the

serial numbers on the map when set ECU (see ECU manual).

5. Using apsystems' mobile app ArrayApp can make the

installation and registion much more simple.

Step 8 - Place a Warning Notice

A warning notice shall be placed in such a position that any person gaining

access to live parts will be warned in advance of the need to isolate those
live parts from all points of supply. Special attention should be paid that the

power supply, measuring circuits (sense lines) and other parts may not be

isolated from the network when the switch of the interface protection is open.

As a minimum, warning labels shall be placed:

On the switchboard (DNO panel and consumer unit) that has the

micro-generator connected to it;

On all switchboards in between the consumer unit and the micro-

generator itself;

On, or in the micro-generator itself;

At all points of isolation for the micro-generator.

Figure 13

Summary of Contents for YC500i Series

Page 1: ...com APsystems Europe Rue des Monts dor ZAC de Folliouses Sud Les Echets 01700 Miribel France TEL 33 481 65 60 40 EMAIL emea APsystems com All Rights Reserved For Europe YC500I Microinverter Please sca...

Page 2: ...ircuit junction box 9 Step 3 Attach the APsystems Microinverters to the racking or the PV module frame 9 Stpe 4 Connect the APsystems microinverter to AC bus cable 10 Step 5 Install a Bus Cable End Ca...

Page 3: ...inverters Perform all electrical installations in accordance with local electrical codes Before installing or using the APsystems Microinverter please read all instructions and cautionary markings in...

Page 4: ...chnical for help Changes or modifications not expressly approved by the party responsible for compliance may void the user s authority to operate the equipment Communication Statement The APsystems En...

Page 5: ...on concerning the decommissioning of equipment CE mark is attached to the solar inverter to verify that the unit follows the provisions of the European Low Voltage and EMC Directives Refer to the oper...

Page 6: ...ctive grid tied applications comprised of three key elements APsystems Microinverter APsystems Energy Communication Unit ECU APsystems Energy Monitor and Analysis EMA web based monitoring and analysis...

Page 7: ...Microin verters are designed to operate at full power at ambient outdoor temper atures of up to 149 F 65 C The inverter housing is designed for outdoor installation and complies with the IP67 environ...

Page 8: ...lso use multiple APsystems Microinverters in the form of single phase grid to achieve three phase grid and operate with most 60 and 72 cell PV modules For more information please see the Technical Dat...

Page 9: ...eplace APsystems Microinverters WARNING Before installing or using an APsystems Microinverter please read all instructions and warnings in the technical documents and on the APsystems Microinverter sy...

Page 10: ...unction box to the point of utility Interconnection WARNING Wiring colour code can be different according local regulation check all the wires of the installation before connecting to the AC bus to be...

Page 11: ...verter to allow proper air flow Stpe 4 Connect the APsystems microinverter to AC bus cable Figure 5 Best Practice Use the Bus Cable Unlock Tool of AC Bus to split the connectors Figure 6 a Check the M...

Page 12: ...w that the Microinverter is functioning correctly This entire check function will start and end within 5 seconds of plugging in the unit so pay careful attention tothese lights when connecting the DC...

Page 13: ...affix one to the respective location on the APsystems installation map and fill in A B in the label below as figure12 according to the layout on the roof as figure 11 Then affix another label to the P...

Page 14: ...y card is located in Appendix last page of this manual 4 You can use Scanning Gun or mobile phone to scan the serial numbers on the map when set ECU see ECU manual 5 Using apsystems mobile app ArrayAp...

Page 15: ...the Microinverters they will start to blink green every 10 seconds 4 Plug in the ECU and follow the instructions according to the manual for the ECU 5 The APsystems Microinverters will start to send p...

Page 16: ...lt error is fixed follow the instructions in the ECU Installation and Operation Manual to clear this GFDI error reporting Other Faults All other faults are reported to the ECU Refer to the ECU Install...

Page 17: ...s from other units most likely a Microinverter problem To troubleshoot a non operating APsystems Microinverter Follow the steps below in order 1 Verify the utility voltage and frequency are within ran...

Page 18: ...the microinverter 3 Cover the module with an opaque cover 4 Disconnect the PV module DC wire connectors from the Microinverter 5 Remove the Microinverter from the PV array racking B Remove the opaque...

Page 19: ...ease refer to the datasheet or usermanual which can be download from APsystems website www APsystems com WARNING You must match the DC operating voltage range of the PV module with the allowable input...

Page 20: ...ure Range 40 C to 65 C Storage Temperature Range 40 C to 85 C Dimensions W x H x D 221mm X 167mm X 29mm Weight 2 5kg AC Bus Maximum Current 20A Connector type MC 4 Type or Customize Enclosure Rating I...

Page 21: ...3 68KVA AC JUNCTION BOX METER 20 AMP CIRCUIT BREAKER PER BRANCH CIRCUIT TO METER OR AC DISTRIBUTION PANEL NEUTRAL GROUND DISTRIBUTION PANEL SINGLE PHASE ENERGY COMMUNICATION UNIT 230 VAC POWER CABLE A...

Page 22: ...location of each microinverter in your PV installation Each APsystems microinverter has a removable serial number label located on the mounting plate Peel the label and affix it to the respective loc...

Reviews: