Technical Specifications
Technical specifications shown here apply at an ambient temperature of 25° C ± 5°.
4.1
AC Output
OUTPUT SPECIFICATIONS - AC MODE
MODEL
CFS108
CFS116
CFS140
Power Rating
800 VA
1600 VA
4000 VA
AC Output Terminals
Rear Panel (L, N, G), Floating Neutral
Voltage
Ranges
Low / High
5 - 150V / 5 - 300V
Resolution
0.1 V
Accuracy
± ( 0.2% s 0.3 V )
Current
150V Range
9.2 A
18.4 A
36.8 A
300V Range
4.6 A
9.2 A
18.4 A
Over Current Capability
4x Rated, 110% for 1000 msec
Peak Cur.
150V Range
36.8 A
73.6 A
147.2 A
300V Range
18.4 A
36.8 A
73.6 A
Crest Factor
≥ 3 to 1
Frequency
Range
40 - 500 Hz
Resolution
0.1 Hz
Accuracy
± 0.1 Hz
Start/Stop
Phase
Range
0 - 359°
Accuracy
±1%, 45- 65 Hz
Harmonic Distortion
(Full Resistive Load)
< 1.0%, 80-140V on Low Range
< 1.0%, 160-280V on High Range
Line Regulation
± 0.1 V for a 10% Line Change
Load Regulation
± 1.0% Range + 1V, R Load
Response time
< 400 µsec
Protection
Over Current, Short Circuit, Over Voltage, Under Voltage, Over
Temperature