Query form:
STATus:OPERation:ENABle?
Value range:
0, 256...3840
Example:
STAT:OPER:ENAB˽1792
Sets the Enable register of the Operation register to value
1792 and enables bits “CV“, “CC“ and “CP“ for reporting
events to the STB.
7.12.6
Set Value Commands
7.12.6.1
[SOURce:]VOLTage
˽
<NRf>[Unit]
Sets the output voltage limit of the unit within a certain range, which is either defined by
adjustment limits ("Limits", where featured) or is 0...102% nominal value, or reads the last
setting. Alternatively, parameters MIN or MAX can be used to instantly set the voltage to
the adjustable MINimum or MAXimum.
Query form:
[SOURce:]VOLTage?
Value range:
<NRf> = 0...1.02 * nominal voltage (according to technical specs)
Examples:
VOLT 12
Absolute short form. Sets 12 V.
SOUR:VOLTAGE˽24.5V
Mixed form short/long, with unit. Sets 24.5 V, unless the
voltage adjustment range has been limited otherwise.
SOURCE:VOLTAGE˽MIN
Sets the voltage to the defined minimum, usually 0 V.
7.12.6.2
[SOURce:]CURRent
˽
<NRf>[Unit]
Sets the input resp. output current limit of the unit within a certain range, which is either
defined by adjustment limits ("Limits", where featured) or is 0...102% nominal value, or
reads the last setting. Alternatively, parameters MIN or MAX can be used to instantly set the
current to the adjustable MINimum or MAXimum.
Query form:
[SOURce:]CURRent?
Value range:
<NRf> = 0...1.02 * nominal current (according to technical specs)
Example:
CURR˽170
Absolute short form. Sets 170 A.
SOUR:CURRENT˽45.3A
Mixed form short/long, with unit. Sets 45.3 A, unless the
adjustment range of the current has been limited
otherwise.
SOURCE:CURRENT˽MAX
Sets the current to the defined maximum, which is either
102% of the rated current of the unit or, if existing for the
particular unit, to the value of adjustment limit "I-max" (also
see 5.4.8).