background image

9

PIC. 11

MANUAL RELEASE

The Aproli 280/700 Strong manual release makes it possible to move the gate manually, in the case of a power failure or during the initial
manual opening and closing tests. The 

manual release lever – S

 can be accessed by opening the 

protection

 

cover

 with the customized

key. Lower the lever in order to release the gate (Pic. 11).

LOWER THE
MANUAL RELEASE
LEVER – 

S

 TO

RELEASE

MANUAL RELEASE
LEVER - 

S

MANUAL RELEASE
LEVER – 

S

 INSIDE

PROTECTION
COVER

FEATURES AND TECHNICAL SPECIFICATIONS

“Elpro 13 CEI” represents the latest state of the art technology for control panels. It is extremely versatile and can meet the most various
requirements. It is fitted with the “Cut Off Switch” by cover knob.
It has the same functions as “Elpro 9” and incorporates additional advantages as follows: Stroke Reversing Pulse, Pedestrian Operating
Mode (where one leaf only can be operated allowing people to walk in/out), STOP and HOLD function by keeping the remote control
button pressed down. Further improvements can be noted in the “Elpro 13 CEI”:
- Addition of a 1 Amp. fuse to the 24 V circuit as a protection for the accessories (remote control - photocells -etc.) which are connected

to the terminals 12 - 13 and for the panel itself in that it can prevent short circuit during installation.

- The pulse to the electric lock is increased to 2 seconds. Releasing is so much easier as the electric lock is released with an anticipation

of 100 msec. before the gate starts moving.

- A 24 V - 3 W lamp indicates gate operations (Gate CLOSED = Lamp OFF - Gate in OPEN cycle = Lamp flashes slowly - Gate OPEN =

Lamp stays ON without flashing - Gate in CLOSE cycle = Lamp flashes fast).

- It provides a better switching intelligence design to enhance the reliability of the relays.
- The Motor Run Time is independent from the Leaf Delay Time in close cycle (the delay time is automatically added to the duration of

the -opening time).

- The 8 Dip-switches can be arranged into any of the possible patterns to achieve the required operating modes without any risk of

interference with one another.

“STROKE REVERSING PULSE” and “S.1A.P.”

Set Dip-switch No. 7 to ON The ”Stroke Reversing Pulse” (S.R.P.) is activated only with the gate in the CLOSE position. The pulse operates
the gate in the CLOSE direction first and then immediately reverses into OPEN (This will help the gate lock to release). All the other
operations will be performed in the standard way. No danger comes from the Stroke Reversing Pulse. This function remains in service
with the panel set to “Pedestrian Mode”. Set Dip-switch No. 6 to ON for “Pedestrian Mode” (S.1A.P.), terminals 3 - 4. Only one leaf is
operated when the OPEN button is pressed down. Automatic reclosing. If the OPEN button is pressed twice in a row, both leafs are
opened. The S.1A.P. function is activated only when the gate is in the fully CLOSE position. The remote control always operates both
gates, terminals 7 - 8.

The box of ELPRO 13 CEI and its cover are made of weather-proof, shock-resistant plastic material which has a degree of protection
equalling IP 437. The cover is fitted with a knob of quick response in case of an emergency by cutting off the voltage supply.

Summary of Contents for 280/700 STRONG

Page 1: ...G B INSTALLATION MANUAL...

Page 2: ...ust be installed and levelled on a flat surface The Aproli 280 700 Strong is an external oil hydraulic gate operator for swing gates with two directional hydraulic locking suitable for gates with very...

Page 3: ...n fact Right and Left are intended for an observer standing in front of the two gate leaves to be opened towards the observer himself Pic 3 I e if the gate opens inwards the observer will be standing...

Page 4: ...CTION ARM The straight arm should be bolted to the bended arm The straight arm offers various different assembly solutions since it has holes for connection with the telescopic arm cover in 3 differen...

Page 5: ...sition using the 4 fixing screws B Pic 5 The following table indicates some installation distances These are not obligatory and are for reference purposes only Pic 8 The distances indicated must be us...

Page 6: ...RM A RISK ANALYSIS IN COMPLIANCE WITH EN 12445 AND EN 12453 STANDARDS AND INSTALL THE NECESSARY SAFETY DEVICES THE FOLLOWING FIGURE PROVIDES AN INDICATION OF THE ESSENTIAL ACCESSORIES FOR THE SYSTEM O...

Page 7: ...1 Amp FUSE 24 V OUTPUT TERMINALS 12 13 LEAF DELAY TIMER CLOSE DWELL TIME MOTOR RUN TIME OPEN CLOSE ON TO 0 THE DELAY IS OUT OF SERVICE MICROPROCESSOR DIP SWITCH TERMINALS FOR THE CONNECTION OF THE PUS...

Page 8: ...AND HOLD AS LONG AS BUTTON DOWN IT OPENS STRAIGHT AWAY N 6 OFF BOTH LEAFS ARE OPERATED N 7 OFF S R P OUT OF SERVICE N 8 OFF LEAF DELAY OPEN CYCLE ONE STARTS BEFORE THE OTHER LAMP ON GATE OPEN LAMP FL...

Page 9: ...3 W lamp indicates gate operations Gate CLOSED Lamp OFF Gate in OPEN cycle Lamp flashes slowly Gate OPEN Lamp stays ON without flashing Gate in CLOSE cycle Lamp flashes fast It provides a better switc...

Page 10: ...i 280 700 Strong are distinguished by different colours on the Right Aproli and the Left Aproli the red regulator adjusts the drive force of the leaf during closing while the green regulator adjusts t...

Page 11: ...me of one complete cycle 76 s No of complete cycles Open Dwell Close 47 cycles hour No of cycles a year 8 hours a day 137 000 OIL HYDRAULIC PUMP Pump flow rate P3 0 85 l min Average working pressure 1...

Page 12: ...ing Mechanical parts maintenance every 6 months approx Electronic apparatus and safety equipment maintenance every month The growth of MECCANICA FADINI has always been based on the development of guar...