FEATURES OF THE ELECTRONIC PROGRAMMER ELPRO 13 CEI FOR

SWINGING GATES

8

All the electrical connections are to be made as per the following instructions and diagrams. Supply the terminals 24-25 with 230V -
50 Hz single phase voltage. The “red LED” switches on and stays on as long as the board is properly supplied. Through the timer No. 9
you can control the running time of the motor in both cycles, OPEN and CLOSE.
Set it so that the running time of the motor is longer than the actual travel of the gate: set the timer No. 8 -DWELL- ie. the interval between
open and re-closing, so that you can meet the required interval of time. The timer No. 7 -LEAF DELAY in “close” cycle- is to be set as
follows: on to “–” (less) the delay is out of service; clockwise on to “+” (more) the delay is operative.
- With the electric motor connected to terminals 19 - 20 - 21: the delay is operative in the “open” cycle, with a factory pre-set time.
- With the electric motor connected to terminals 16 - 17 - 18: the delay is operative in “close” cycle and can be adjusted through the
timer No. 7 on to “less” or “more”.
LOGIC OF THE ELECTRONIC PROGRAMMER: When a pulse is given, the flashing light switches on. After three seconds the motors start.
During the interval before re-closing, the light stays on. When the gates are fully re-closed, the light keeps on flashing for three more
seconds and then switches off automatically.
The 3 second interval (pre-flashing) which precedes the actual start of the motors can be eliminated by means of the DIP-SWITCH “B” No.4.

LED No. 1: It switches on when voltage is supplied.
LED No. 2: “PHOTOCELLS”. Normally on. It switches off when the photocells are obstructed.
LED No. 3: “OPEN”. It switches on when the respective switch is activated.
LED No. 4: “CLOSE”. It switches on when the respective switch is activated.
LED No. 5: “STOP”. Normally on. It switches off when the respective switch is activated.
LED No. 6: “RADIO”. It switches on whenever a pulse is given, either from remote control, keyswitch or push buttons.

DIP-SWITCH B SETTING IN ELPRO 13 CEI
N

°

 1 OFF  = PHOTOCELLS. NO STOP IN OPEN CYCLE. REVERSE/CLOSE

N

°

 2 OFF  = REMOTE CONTROL. REVERSE

N

°

 3 OFF  = NO AUTOMATIC RECLOSING

N

°

 4 OFF  = NO PRE-FLASHING

N

°

 5 OFF  = REMOTE CONTROL. NO STOP AND HOLD AS LONG

   AS BUTTON DOWN. IT OPENS STRAIGHT AWAY

N

°

 6 OFF  = BOTH LEAFS ARE OPERATED

N

°

 7 OFF  = S. R. P. OUT OF SERVICE

N

°

 8 OFF  = LEAF DELAY OPEN CYCLE.

   ONE STARTS BEFORE THE OTHER

LAMP ON

= GATE OPEN

LAMP FLASHES SLOWLY = GATE OPENING
LAMP FLASHES FAST 

= GATE CLOSING

LAMP OFF

= GATE CLOSED

1) It is advisable not to expose the control box directly to weather conditions; if mounted outside, a suitable enclosure is recommended

to protect it from sunshine and rain.

2) Bridge terminals 1 - 2 if you do not require any photocells.
3) Should two sets of photocells be required, these are to be series connected to terminals 1 - 2, contact normally closed.
4) Bridge terminals 6 - 8 if you do not require any keyswitch or push buttons.
5) Fit the mains to the control box with a high sensitivity, differential, magnetic-thermal switch, 0.03 Amps.
6) OPERATING MODE WITH TWO PAIRS OF PHOTOCELLS, INDEPENDENT FROM EACH OTHER

Dip-switch No. 1 set to OFF, connect the pair of photocells that are inside the property to the terminals marked “2

nd

 pair”.

The second pair always stops the gate in open cycle in case of an obstacle.
During close cycle the second pair reverses the gate direction.

7) NOTE WELL

FAULT FINDING:
- Check supply voltage with a tester: it must be 230 V, single-phase.
- Check the high voltage fuses.
- Check the low voltage fuses.
- Check if the photocell contacts are normally closed.
- Check voltage from the control box to the electric motor(s): power might have dropped.
- The section of the electric cables to the motor(s) must not be less than 1.5 mm

2

.

- Connect the other pair to the terminals 1 - 2
This pair performs in the standard pre-set mode, ie:
no stop during open cycle, REVERSING GATE DIRECTION DURING CLOSE CYCLE.
Terminals to stay linked out should the second pair of photocells not be used, and set the desired operating mode through Dip-switch No. 1.

* 24 V ~ output. Terminals 12 - 13. It can supply power for 2 pairs of photocells plus 1 radio receiver.

Terminal 11 provides a power output for a lamp. 24 V - 3 W max.
Flashing lamp output. Terminals 22 - 23. Maximun available power 25 W max.

N

°

 1 ON  = STOP DURING OPEN CYCLE

N

°

 2 ON  = NO REVERSE DURING OPEN CYCLE

N

°

 3 ON  = AUTOMATIC RECLOSING

N

°

 4 ON  = PRE-FLASHING

N

°

 5 ON  = STOP AND HOLD AS LONG AS

 

   THE BUTTON IS KEPT DOWN

N

°

 6 ON  = PEDESTRIAN. ONE LEAF ONLY

   GATES IN CLOSE POSITION

N

°

 7 ON  = S. R. P. IN SERVICE

   GATES IN CLOSE POSITION

N

°

 8 ON  = NO LEAF DELAY

  BOTH MOTORS START TOGETHER

Summary of Contents for 280/700 STRONG

Page 1: ...G B INSTALLATION MANUAL...

Page 2: ...ust be installed and levelled on a flat surface The Aproli 280 700 Strong is an external oil hydraulic gate operator for swing gates with two directional hydraulic locking suitable for gates with very...

Page 3: ...n fact Right and Left are intended for an observer standing in front of the two gate leaves to be opened towards the observer himself Pic 3 I e if the gate opens inwards the observer will be standing...

Page 4: ...CTION ARM The straight arm should be bolted to the bended arm The straight arm offers various different assembly solutions since it has holes for connection with the telescopic arm cover in 3 differen...

Page 5: ...sition using the 4 fixing screws B Pic 5 The following table indicates some installation distances These are not obligatory and are for reference purposes only Pic 8 The distances indicated must be us...

Page 6: ...RM A RISK ANALYSIS IN COMPLIANCE WITH EN 12445 AND EN 12453 STANDARDS AND INSTALL THE NECESSARY SAFETY DEVICES THE FOLLOWING FIGURE PROVIDES AN INDICATION OF THE ESSENTIAL ACCESSORIES FOR THE SYSTEM O...

Page 7: ...1 Amp FUSE 24 V OUTPUT TERMINALS 12 13 LEAF DELAY TIMER CLOSE DWELL TIME MOTOR RUN TIME OPEN CLOSE ON TO 0 THE DELAY IS OUT OF SERVICE MICROPROCESSOR DIP SWITCH TERMINALS FOR THE CONNECTION OF THE PUS...

Page 8: ...AND HOLD AS LONG AS BUTTON DOWN IT OPENS STRAIGHT AWAY N 6 OFF BOTH LEAFS ARE OPERATED N 7 OFF S R P OUT OF SERVICE N 8 OFF LEAF DELAY OPEN CYCLE ONE STARTS BEFORE THE OTHER LAMP ON GATE OPEN LAMP FL...

Page 9: ...3 W lamp indicates gate operations Gate CLOSED Lamp OFF Gate in OPEN cycle Lamp flashes slowly Gate OPEN Lamp stays ON without flashing Gate in CLOSE cycle Lamp flashes fast It provides a better switc...

Page 10: ...i 280 700 Strong are distinguished by different colours on the Right Aproli and the Left Aproli the red regulator adjusts the drive force of the leaf during closing while the green regulator adjusts t...

Page 11: ...me of one complete cycle 76 s No of complete cycles Open Dwell Close 47 cycles hour No of cycles a year 8 hours a day 137 000 OIL HYDRAULIC PUMP Pump flow rate P3 0 85 l min Average working pressure 1...

Page 12: ...ing Mechanical parts maintenance every 6 months approx Electronic apparatus and safety equipment maintenance every month The growth of MECCANICA FADINI has always been based on the development of guar...

Reviews: