Once all the electrical connections have been made, carry out the initial operation tests, adjust the motor run timer 

09

 for a period of

4-5 seconds more than the real gate opening time; the dwell timer 

08

, and the leaf closure delay 

07

 (Pic. 10)

In order to set automatic or semiautomatic operation, flick the Dip-switch B:
-

Automatic Operation

: with dip-switch lever No. 3 in the 

ON

 position, once the opening pulse has been given (contact 4 and 8 on the

Elpro 13 CEI programmer terminal box), the gate opens and dwells for the time set by the potentiometer 08, then closes automatically.

-

Semiautomatic Operation

: with dip-switch lever No. 3 in the 

OFF

 position, once the opening pulse has been given, the gate opens,

while a closing pulse must be given in order to close in (contact 5 and 8 on the Elpro 13 CEI programmer terminal box).

-

Radio Contact

: contact 7 and 8 on the Elpro 13 CEI electronic programmer terminal box (Pic. 10), the automation reverses the movement

that it is carrying out upon every pulse from the keyswitch, the transmitter or the wall push buttons (it is advisable to read the instructions
leaflet enclosed with the electronic programmer carefully).

WARNING: If the electric motors have insufficient drive power due to shortage of electric current, add two 12 

µ

F capacitors (one for

each electric motor), connecting them in parallel to the individual electric motor phases.

 

13

 

CEI

FOR SWING GATES - SINGLE-PHASE

Drwg. No. 

2014

230 V - 25 W max

FLASHING LAMP

COMMON

COMMON

ELECTRIC MOTORS
SINGLE-PHASE

230 V SINGLE-PHASE
SUPPLY VOLTAGE

CAPACITORS

CUT OFF SWITCH
BY COVER KNOB

1 Amp. FUSE:
24 V OUTPUT
TERMINALS 12 - 13

LEAF DELAY
TIMER
CLOSE

DWELL TIME

MOTOR RUN
TIME OPEN
& CLOSE

ON TO “0” THE DELAY
IS OUT OF SERVICE

MICROPROCESSOR

DIP-SWITCH

TERMINALS FOR THE
CONNECTION OF THE
PUSH BUTTONS PULIN 3

RADIO CONTROL
PLUG-IN CARD SUPPORT

24 V OUTPUT

1

°

 CHANNEL

ON

OFF

N.W.: THIS PANEL IS TESTED TO OPERATE GATES ONLY THROUGH FADINI
ACCESSORIES. NO GUARANTEE FOR ACCESSORIES OF OTHER MAKE OR
SPECIAL APPLICATIONS.

PEDESTRIAN MODE
ONE PULSE OPENS
ONE GATE LEAF ONLY

PULSE TWICE

CONSECUTIVELY TO OPEN

BOTH GATE LEAFS

ALL OPERATIONS

OPEN, CLOSE & REVERSE

RADIO CONTACT

N. W.: for special applications, ie. to switch on lights - CCTV etc…, SOLID
STATE RELAYS are recommended to be used only.
Standard relays would affect the micro-processor.

12,5 

µ

F

12,5 

µ

F

B

Should more pairs of photocells be required

than the recommended quantity

, fit an

auxiliary transformer outside the control box.

LED 1: LIGHTS UP WHEN THE CARD IS POWERED
LED 2: SWITCHES OFF WHEN THERE IS AN OBSTACLE IN FRONT

OF THE PHOTOCELLS

LED 3: OPEN. LIGHTS UP UPON OPENING PULSE
LED 4: CLOSE. LIGHTS UP UPON CLOSE PULSE
LED 5: STOP, SWITCHES OFF UPON STOP PULSE
LED 6: RADIO, LIGHTS UP UPON EVERY RADIO PULSE

OPEN SWITCH N.O. CONT

ACT

COMMON

N.C. CONT

ACT

.

PHOTOCELLS

CLOSE SWITCH N.O. CONT

ACT

STOP SWITCH N.C. CONT

ACT

RADIO CONT

ACT N.O.

COMMON

VOL

TAGE OUTPUT

ELECTRIC LOCK SUPPL

Y

24 V - 3 W max. INDICA

TOR

24 V

ac OUTPUT

Max. permitted load:

2 pairs photocells

1 radio receiver

-PHOTOCELLS 2

nd

 P

A

IR-

INSIDE PHOTOCELLS N.C. contact. If

obstructed, they prevent the gates from

opening, reverse gate direction during

close cycle.

+

7

8

9

+

+

FADINI

26
27
28

3

4

7

8

ON

1 2

4

3

5 6 7 8

1

2

3

4

5

6

M1

16

25

24

23

22

21

20

19

18

17

M2

5 Amp.
FUSE

4

3

2

1

13

12

11

10

9

8

7

6

5

5 Amp.
FUSE

630 mA
FUSE

F4

F2

F3

F1

630 mA

FUSE

FLASHING

LAMP

F5

0

Summary of Contents for 280/700 STRONG

Page 1: ...G B INSTALLATION MANUAL...

Page 2: ...ust be installed and levelled on a flat surface The Aproli 280 700 Strong is an external oil hydraulic gate operator for swing gates with two directional hydraulic locking suitable for gates with very...

Page 3: ...n fact Right and Left are intended for an observer standing in front of the two gate leaves to be opened towards the observer himself Pic 3 I e if the gate opens inwards the observer will be standing...

Page 4: ...CTION ARM The straight arm should be bolted to the bended arm The straight arm offers various different assembly solutions since it has holes for connection with the telescopic arm cover in 3 differen...

Page 5: ...sition using the 4 fixing screws B Pic 5 The following table indicates some installation distances These are not obligatory and are for reference purposes only Pic 8 The distances indicated must be us...

Page 6: ...RM A RISK ANALYSIS IN COMPLIANCE WITH EN 12445 AND EN 12453 STANDARDS AND INSTALL THE NECESSARY SAFETY DEVICES THE FOLLOWING FIGURE PROVIDES AN INDICATION OF THE ESSENTIAL ACCESSORIES FOR THE SYSTEM O...

Page 7: ...1 Amp FUSE 24 V OUTPUT TERMINALS 12 13 LEAF DELAY TIMER CLOSE DWELL TIME MOTOR RUN TIME OPEN CLOSE ON TO 0 THE DELAY IS OUT OF SERVICE MICROPROCESSOR DIP SWITCH TERMINALS FOR THE CONNECTION OF THE PUS...

Page 8: ...AND HOLD AS LONG AS BUTTON DOWN IT OPENS STRAIGHT AWAY N 6 OFF BOTH LEAFS ARE OPERATED N 7 OFF S R P OUT OF SERVICE N 8 OFF LEAF DELAY OPEN CYCLE ONE STARTS BEFORE THE OTHER LAMP ON GATE OPEN LAMP FL...

Page 9: ...3 W lamp indicates gate operations Gate CLOSED Lamp OFF Gate in OPEN cycle Lamp flashes slowly Gate OPEN Lamp stays ON without flashing Gate in CLOSE cycle Lamp flashes fast It provides a better switc...

Page 10: ...i 280 700 Strong are distinguished by different colours on the Right Aproli and the Left Aproli the red regulator adjusts the drive force of the leaf during closing while the green regulator adjusts t...

Page 11: ...me of one complete cycle 76 s No of complete cycles Open Dwell Close 47 cycles hour No of cycles a year 8 hours a day 137 000 OIL HYDRAULIC PUMP Pump flow rate P3 0 85 l min Average working pressure 1...

Page 12: ...ing Mechanical parts maintenance every 6 months approx Electronic apparatus and safety equipment maintenance every month The growth of MECCANICA FADINI has always been based on the development of guar...

Reviews: