6
ELECTRICAL CONNECTIONS TO THE ELPRO 13 CEI PROGRAMMER
PIC. 9
Before making any connections, study the enclosed electrical diagrams carefully.
IMPORTANT: The whole electrical system must be earthed (Pic. 9); DO NOT CUT the electric cable for installation requirements; CUT
OFF the 230 V power supply (line switch not connected. (Pic. 9), during the electric wiring installation and connection phase.
-
Power supply, electric motor and flashing light
connections are made with electric cables with a section of 1.5 mm
2
for a maximum
distance of 50 m. For distances of over 50 metres, we recommend using electric cables with a section of 2 mm
2
.
-
For limit switches, photocells, pushbuttons and accessories
use cables with 1 mm
2
wires (Pic. 9)
IMPORTANT: PERFORM A RISK ANALYSIS IN COMPLIANCE WITH EN 12445 AND EN 12453 STANDARDS AND INSTALL THE NECESSARY
SAFETY DEVICES. THE FOLLOWING FIGURE PROVIDES AN INDICATION OF THE ESSENTIAL ACCESSORIES FOR THE SYSTEM OPERATION.
THE SYSTEM SHOULD BE CUSTOMIZED AT THE INSTALLER AND USER’S DISCRETION DEPENDING ON THE VARIOUS REQUIREMENTS
AND CHARACTERISTICS OF THE ENVIRONMENT.
1) “ELPRO 13 CEI” PROGRAMMER WITH PLUG-IN JUBI 433 RADIO RECEIVER
2) 0.03 A MAGNETO-THERMAL DIFFERENTIAL SWITCH
3) JUNCTION BOX
4) LEFT-HAND APROLI 280/700 STRONG
5) PHOTOCELL TRANSMITTER POLO 44 ON POST
6) GATE STOP IN OPEN GATE POSITION
7) JUBI SMALL 433 TRANSMITTER
8) ELECTRIC LOCK
9) PHOTOCELL RECEIVER POLO 44 ON POST
10) RIGHT-HAND APROLI 280/700 STRONG
11) ENCODED KEYSWITCH PRIT 19
12) MIRI 4 FLASHING LIGHT FITTED WITH BIRIO ANTENNA
13) PHOTOCELL TRANSMITTER POLO 44
14) PHOTOCELL RECEIVER POLO 44
LEFT-HAND APROLI ELECTRIC
MOTOR TERMINAL BOX
1
2
3
4
5
6
7
8
9
6
10
11
12
13
14
Summary of Contents for 280/700 STRONG