ADJUSTING THE LEAF DRIVE FORCE
During the initial manoeuvre operations it will be necessary to calibrate the opening and closing drive force that each individual Aproli
280/700 Strong exercises on the leaves; it is therefore necessary to remove the
protection cover
(Pic. 12), firstly using the customized
key on the cover, thereby exposing the automation and the individual pressure regulators that can be adjusted using a flat screwdriver.
NOTE: during factory production, the two hydraulic pressure regulators on each individual Aproli 280/700 Strong are distinguished by
different colours: on the Right Aproli and the Left Aproli, the
red regulator
adjusts the drive force of the leaf during closing, while the
green regulator
adjusts the drive force of the leaf during opening (Pic.12)
PIC. 12
LEFT-HAND APROLI 280/700 STRONG
RIGHT-HAND APROLI 280/700 STRONG
DRIVE FORCE
ADJUSTMENT
VALVES
PROTECTION
COVER
COVER FIXING
SCREWS -
A
CLOCKWISE=
MORE DRIVE
FORCE
ANTICLOCKWISE=
LESS DRIVE FORCE
GREEN
REGULATOR =
DRIVE DURING
OPENING
RED
REGULATOR = DRIVE
DURING
CLOSING
MANUAL RELEASE
LEVER –
S
DRIVE FORCE
ADJUSTMENT
VALVES
LEFT-HAND APROLI 280/700 STRONG
RIGHT-HAND APROLI 280/700 STRONG
GREEN
REGULATOR =
DRIVE DURING
OPENING
RED
REGULATOR =
DRIVE DURING
CLOSING
MANUAL RELEASE
LEVER –
S