AXONE: ELECTRICAL ERRORS
Lambda probe P0130
- short circuit to positive.
Error cause
•
Excessive voltage (battery voltage) has been detected at PIN 43 of the ENGINE connector.
Caution: the "lambda probe" parameter is not the real value that is read; a recovery value
is displayed instead.
Troubleshooting
•
If shorted to positive: with key set to ON, disconnect the sensor connector and measure PIN
1 voltage on the cable harness side (grey cable): if there is voltage (5 or 12 V), restore the
cable harness; if there is not, replace the lambda probe.
Lambda probe heating P0135 -
short circuit to positive / open circuit, short circuit to negative.
Error cause
•
If shorted to positive: excessive voltage has been detected at PIN 32 of the ENGINE con-
nector.
•
If the circuit is open, short circuit to negative: voltage equal to zero has been detected at
PIN 32 of the ENGINE connector.
Troubleshooting
•
If shorted to positive: disconnect the probe connector and check the sensor correct resist-
ance: replace the sensor if not OK; if it is OK, restore the cable harness.
•
if the circuit is open, short circuit to negative: check the continuity from probe connector (PIN
3 and 4) towards the probe: if not OK, replace the probe; if it is correct, check the sensor
connector and the Marelli control unit connector. If not OK, restore. If OK, and with key set
to ON and sensor connector disconnected, check if there is battery voltage at PIN 4: if there
is not, check the red/black cable between the probe connector and the auxiliary injection
relay (No. 42 in the wiring diagram, located under fuel tank, right side, third relay starting
from the front; however, the identification of the relay with the colour of the cables). If there
are also coil and injector errors, check the relay and its excitation and power line; if there is
voltage at PIN 4, check the grey/blue cable earth insulation (PIN 3): if not OK, restore the
cable harness. If it is OK, check the continuity of the grey/blue cable (between the sensor
connector PIN 3 and the ENGINE PIN 32) and restore the cable harness.
AXONE: LOGIC ERRORS
Lambda probe P0134
- voltage without variation.
Error cause
•
An abnormal behaviour of the voltage at PIN 43 of the ENGINE connector has been detec-
ted: the voltage, that should vary over time, keeps a constant value instead.
Troubleshooting
Electrical system
SL 750 SHIVER
ELE SYS - 50
Summary of Contents for SL 750 SHIVER
Page 1: ...SERVICE STATION MANUAL 854146 SL 750 SHIVER ...
Page 4: ......
Page 6: ......
Page 7: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Page 28: ...Characteristics SL 750 SHIVER CHAR 22 ...
Page 29: ...INDEX OF TOPICS SPECIAL TOOLS S TOOLS ...
Page 37: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Page 50: ...Maintenance SL 750 SHIVER MAIN 14 ...
Page 51: ...INDEX OF TOPICS TROUBLESHOOTING TROUBL ...
Page 59: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Page 76: ...Electrical system SL 750 SHIVER ELE SYS 18 ...
Page 141: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Page 148: ...Engine from vehicle SL 750 SHIVER ENG VE 8 ...
Page 149: ...INDEX OF TOPICS ENGINE ENG ...
Page 222: ...Engine SL 750 SHIVER ENG 74 ...
Page 223: ...INDEX OF TOPICS POWER SUPPLY P SUPP ...
Page 230: ...Power supply SL 750 SHIVER P SUPP 8 ...
Page 231: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Page 257: ...INDEX OF TOPICS CHASSIS CHAS ...
Page 267: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Page 274: ...Braking system SL 750 SHIVER BRAK SYS 8 ...
Page 275: ...INDEX OF TOPICS CLUTCH SYSTEM CLU SYS ...
Page 277: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Page 286: ...Cooling system SL 750 SHIVER COOL SYS 10 ...
Page 287: ...INDEX OF TOPICS BODYWORK BODYW ...