DUCT COLLAR INSTALLATION
HORZONTAL DISCHARGE:
• Use the screws in the parts bag to attach the duct collars to the
inlet and outlet of the dehumidifier� The outlet collar has a backflow
damper�
• The outlet duct collar may be attached to the top or end of the unit�
Move the outlet cover to the location not being used� See
FIGURE 7
�
• Make sure there are no bends in the ductwork coming off the outlet
for a minimum of 4"� This will ensure that the ductwork will not
interfere with the backflow damper function�
VERTICAL DISCHARGE:
Use the screws provided in the parts bag to attach the duct collars:
• When the dehumidifier requires a ducted vertical discharge, remove
the top access panel and remount on the outlet of the unit� Install
the outlet duct collar with backflow damper on top of the unit� See
FIGURE 7
�
CONTROL LOCATION
The on-board control can be located on the top of the
dehumidifier or can be relocated to the front of the
dehumidifier if the control can not be seen/accessed in
the top orientation�
TO MOVE THE CONTROL:
1.
Remove the front control panel cover�
2.
Remove the filter access door and filter�
3.
Detach the on-board control by removing the four
(4) screws around the control�
Note:
Use one hand
to support the bottom of the on-board control
when removing�
4.
Keep the control in the unit and relocate to the front
access hole�
5.
Secure the control with the same four screws used
to attach the control to the top of the unit�
6.
Secure the control panel cover to the top of the unit�
OUTLET COVER
OUTLET DUCT
COLLAR W/BACK
DRAFT DAMPER
MOVE OUTLET
COVER AND
INSTALL OUTLET
DUCT COLLAR TO
TOP DISCHARGE
LOCATION
INLET
DUCT
COLLAR
INLET
DUCT
COLLAR
END DISCHARGE
TOP DISCHARGE
CONTROL
PANEL COVER
CONTROL
CONTROL
CONTROL
PANEL COVER
FILTER ACCESS DOOR
90-2393
90-2017
FIGURE 7
– FULLY DUCTED INSTALLATIONS
FIGURE 8
– CONTROL LOCATION
6