4
TECHNICAL DATA
1.1 TECHNICAL DATA AND DIMENSIONS APRICUS GK1620 / GK2020 / GK2620
1.2 DATA PLATE
Left outside of cabinet
1.3 GAS TYPE
The temporary gas label is located on the left outside of cabinet.
The label is the gas that this appliance is designed to operate with.
DO NOT OPERATE WITH ANY OTHER GAS TYPE.
MODELS
GK1620
GK2020
GK2620
Nominal hourly gas consumption
by proportional electronic gas control
MJ/h
125
160
200
Test point pressure (NG)
.40
.56
.68
Test point pressure (LPG)
.40
.61
.70
Water heating capacity raised 40
℃
L/M
10
12.5
16.25
Maximum working pressure
kPa
1200
Gas injectors diameter (NG)
mm
1.35/1.65
1.34/1.65
Gas injectors diameter (LPG)
mm
1.35/1.65
1.0/1.2
Input voltage single phase 50Hz
V
240
Maximum output current
Amp
0.37
0.45
0.47
6$,*$SSURYDOFHUWL¿FDWHQR
GSCS20021
Inlet gas connection male thread
mm
18
Cold water connection male thread
mm
13
18
Hot water conncetion male thread
mm
13
18
Releif valve pressure setting
kPa
1400
Weight dry
kg
16
17
Dimensions (DxWxH)
mm
165 x 350 x 575