16
FAULT MONITOR
THE APRICUS HOT WATER UNIT HAS A SELF DIAGNOSING FUNCTION FOR FAULTS
FAULT MONITOR
:KHQWKHXQLWGRHVQRWRSHUDWHFRUUHFWO\WKHUHGLQGLFDWRULVÀDVKHGRQ3&%
7KHFDXVHRIWKHIDXOWFDQEHGHWHUPLQHGDIWHUFKHFNLQJWKHQXPEHURIÀDVKLQJRQ3&%
PLEASE NOTE ONLY AUTHORISED PERSONS ARE TO PERFORM SERVICE WORK
ON THIS APPLIANCE FAILURE TO COMPLY TO THIS CONDITION WILL VOID THE
WARRANTY AND COULD MAKE THE APPLIANCE UNSAFE.
PLEASE NOTE REPLACEMENT POWER CORD FOR THIS APPLIANCE CAN BE
OBTAINED FROM THE APRICUS SERVICE DEPARTMENT TELEPHONE 1300 277 428.
SCHEDULED SERVICE PERIODS
This water heater requires scheduled maintenance at regular 12 monthly periods to obtain the
maximum service life and safe operation.
PLEASE NOTE FAULTS CAUSED BY INSUFFICIENT GAS SUPPLY, INCORRECT GAS
PIPE SIZE, INSUFFICIENT WATER SUPPLY, GAS QUALITY, WATER QUALITY,
INSTALLATION ERRORS OR OPERATION ERRORS ARE NOT COVERED BY THE
APRICUS WARRANTY. REFER TO PAGE 17 FOR DETAILS.
NUMBER OF
FLASHING
PROBLEM
REMEDY
1
GAS BURNER FAILS TO IGNITE.
CHECK GAS SUPPLY.
2
FALSE FLAME DETECTION.
CALL SERVICE CENTRE.
3
LOSS OF COMBUSTION.
CHECK GAS SUPPLY AND PRESSURE.
4
RESIDUAL FLAME SAFETY DEVICE.
CALL SERVICE CENTRE.
5
THERMISTOR WIRE BREAKAGE.
CALL SERVICE CENTRE.
7
COMBUSTION FAN FAILURE.
CALL SERVICE CENTRE.