Revision 5
- 55 -
November 2017
Maintenance
UV Lamp/Quartz Tube Installation/Replacement Instructions
WARNING:
The quartz tubes and UV lamps are made of glass, and as such are very fragile.
Handle the quartz tubes and UV lamps carefully at all times.
CAUTION:
Do not touch the UV lamp glass with your fingers.
Replace the UV Lamp
1.
Gently pull the black retainer from the end of the Remedy® chamber.
2.
Unplug the four-pin socket from the wire harness to the UV lamp.
3.
Carefully remove the UV lamp from the quartz tube inside the Remedy® chamber.
CAUTION
: Do not touch the UV lamp glass with your fingers. Only handle the UV lamp by the
ceramic ends.
IMPORTANT
: Be sure to pull the UV lamp straight away from the Remedy® chamber until it
is clear of the structure; if the UV lamp is not removed straight and carefully, it may crack or
break the fragile quartz tube.
4.
Carefully slide a UV lamp into the quartz tube inside the Remedy® chamber. As before,
be sure to insert the UV lamp straight and carefully, so you do not crack or break the
quartz tube (or the UV lamp).
5.
Plug the 4-pin socket from the wire harness into the UV lamp.
6.
Secure the UV lamp into the Remedy® chamber with the black retainer.
Replace the Quartz Tube
1.
Gently pull the black retainer from the end of the Remedy® chamber.
2.
Unplug the four-pin socket from the wire harness to the UV lamp.
3.
Carefully remove the UV lamp from the quartz tube inside the Remedy® chamber.
CAUTION
: Do not touch the UV lamp glass with your fingers. Only handle the UV lamp by the
ceramic ends.
IMPORTANT
: Be sure to pull the UV lamp straight away from the Remedy® chamber until it
is clear of the structure; if the lamp is not removed straight and carefully, it may crack or break
the fragile quartz tube.
4.
Unscrew the PVC Reducer Bushing from the end of the Remedy® tank chamber.
5.
Now that the quartz tube is empty, place one finger inside the quartz tube and apply very
gentle pressure to the inside of the quartz tube and carefully pull. With the other hand,
gently push on the opposite end of the quartz tube. This should allow the quartz tube to
slide out of the Remedy® chamber. Remove the O-rings from the Remedy® chamber (if
they did not come out with the quartz tube).
IMPORTANT
: Be sure to pull the quartz tube straight away from the Remedy® chamber until
it is clear of the structure; if the quartz tube is not removed straight and carefully, it may crack or
break.
Summary of Contents for Advantage 6000 Series
Page 4: ......
Page 10: ......
Page 11: ...Revision 5 11 November 2017 Bathing System Operation 6000 Series 6300 Series ...
Page 12: ......
Page 22: ......
Page 23: ...Revision 5 23 November 2017 Remedy UV Infection Protection System Cleaning Disinfecting ...
Page 24: ......
Page 26: ......
Page 27: ...Revision 5 27 November 2017 Whirlpool Advantage Bathing System 6000 Series 6300 Series ...
Page 28: ......
Page 34: ......
Page 35: ...Revision 5 35 November 2017 Air Spa Advantage Bathing System 6000 Series 6300 Series ...
Page 36: ......
Page 42: ......
Page 43: ...Revision 5 43 November 2017 Level Glide Transfer System ...
Page 44: ......
Page 53: ...Revision 5 53 November 2017 Maintenance ...
Page 54: ......