Installing PXI EMC Filler Panels
To ensure specified EMC performance, PXI EMC filler panels must be properly installed in
your NI FlexRIO system. The PXI EMC filler panels (National Instruments part number
778700-01) must be purchased separately.
1.
Remove the captive screw covers.
2.
Install the PXI EMC filler panels by securing the captive mounting screws to the chassis,
as shown in the figure below. Make sure that the EMC gasket is on the right side of the
PXI EMC filler panel.
Figure 6.
PXI EMC Filler Panels and Chassis
1
1
3
2
1. Captive Screw Covers
2. Captive Mounting Screws
3. EMC Gasket
Note
You must populate all slots with a module or a PXI EMC filler panel to
ensure proper module cooling. Do not over tighten screws (2.5 lb · in.
maximum). For additional information about the use of PXI EMC filler panels
in your PXI system, visit
ni.com/info
and enter
emcpanels
.
NI FlexRIO FPGA Module Signals
The following figure shows the available signals on the NI FlexRIO FPGA module. Refer to
your adapter module specifications for your adapter module pinout.
10
|
ni.com
|
NI PXIe-7971R FPGA Module Getting Started Guide