Summary of Contents for REVAMP2600

Page 1: ...REVAMP2600 Instruction manual ...

Page 2: ......

Page 3: ...Instruction manual REVAMP2600 3 REVAMP2600 MANUAL ...

Page 4: ... recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplifier be protected by hearing protection while installing or operating this unit Read all documentation before operating your equipment Keep all documentation for future reference Save the carton and packing material even if the equipment has arrived in good condition Should you ever...

Page 5: ...y distort the normal flow of air around the unit If the unit is used in an extremely dusty or smoky environment the unit should be periodically blown free of dust Do not remove the cover Removing the cover will expose you to potentially dangerous volt ages Do not drive the inputs with a signal level higher than that required to drive equipment to full output Do not run the output of any amplifier ...

Page 6: ...ocessor DSP with easy one button operation simply push the button to select an operating mode making this amplifier the ideal multi purpose tool for your applications LF filter for increased stability when using 100 volt transformers on the output allowing you to use 100 volt speakers as top speakers combined with a standard low impedance subwoofer for example Integrated APC limiter compressor Int...

Page 7: ...ure protect input overload Individual channel mute buttons and versatile LED status indicators This unit has NOT been designed for use in mobile applications such as mobile discobars mobile PA systems Live bands audio rental systems Removable rack ears Note the integrated APC limiter will automatically limit the incoming audio signal to avoid overloads This feature can not be defeated and acts as ...

Page 8: ...ust the input gain to the output level of your source Make sure to avoid the clip led lighting up at the strongest input peak level 4 Channel 1 input gain setting Adjust the input gain to the output level of your source Make sure to avoid the clip led lighting up at the strongest input peak level 5 DSP selector switch with led indicators push the button to scroll between the various pre programmed...

Page 9: ...ink cinch connector connect the line level input signal for channel 2 here Line level is 0 dBV Input and link connector are internally connected 1 on 1 11 Channel 1 unbalanced input and link cinch connector connect the line level input signal for channel 1 here Line level is 0 dBV Input and link connector are internally connected 1 on 1 This connector is also used when DSP mode CH1 SUB CH2 TOP is ...

Page 10: ... This led will also light up when the internal limiter is activated to avoid the amplifier from being overloaded by high input signals The CLIP OVERLOAD led indicates that the power amplifier is clipping reduce the input signal at once whenever this occurs The green SIGNAL 40dB led will light up when an input signal is present The red INPUT OVERLOAD indicates that the input is being overloaded Red...

Page 11: ...when the internal limiter is activated to avoid the amplifier from being overloaded by high input signals The CLIP OVERLOAD led indicates that the power amplifier is clipping reduce the input signal at once whenever this occurs The green SIGNAL 40dB led will light up when an input signal is present The red INPUT OVERLOAD indicates that the input is being overloaded Reduce the incoming signal at on...

Page 12: ...ations 4 CH1 TRAFO CH2 full range led 2 channel 1 is optimized for transformer loads channel 2 is optimized for low impedance applications 5 CH1 SUB CH2 TRAFO TOP led 1 led 3 frequencies below 100 Hz are sent to the sub channel CH1 Frequencies above 100 Hz are sent to the top channel CH2 Filter slope is fixed 12 dB oct or second order Butterworth characteristic Channel 2 is optimized for transform...

Page 13: ...signal from channel 1 is used for both channels 9 CH1 TRAFO linked CH2 TRAFO led 2 led 3 led 4 channel 1 and 2 are optimized for transformer loads The input signal from channel 1 is used for both channels 10 CH1 SUB linked CH2 TRAFO TOP led 1 led 3 led 4 frequencies below 100 Hz are sent to the sub channel CH1 Frequencies above 100 Hz are sent to the top channel CH2 Filter slope is fixed 12 dB oct...

Page 14: ...ower amplifiers are hard workers and their behaviour is similar to human beings In extreme conditions human beings are not able to perform efficiently This also applies to amplifiers It is generally a bad idea to mount multiple heat generating units such as amplifiers in the same rack If necessary use an additional forced ventilation system in your mounting rack The mains fuse is located inside th...

Page 15: ...h 1 2 0 05 100 W 4 Ω 1 kHz A weighted Frequency response 10 24 kHz 0 3 dB Built in DSP yes Protection circuits over current over temperature DC offset AC and DC over and undervoltage Channel separation 67 dB 1 kHz Damping factor 60 all channels APC sytem internal compressor and clip limiter Power amp topology class H Power supply toroidal transformer Cooling forced Max power consumption 1840W Oper...

Page 16: ...16 PROFESSIONAL POWER AMPLIFIER ...