background image

 

               APAR - Sales Office 

              05-090 Raszyn, ul. Gałczyńskiego 6 
              Tel. (+48) 22-101-27-31, 22-853-48-56, 22-853-49-30 
              fax (+48) 22-101-27-33 
              Internet: 

www.apar.pl

, email:  

[email protected]

 

 
 

USER MANUAL 

 

 

 

 

                        

 

            AR431   

 

 

 

     AR432 

 

 

 

            AR435   

 

 

 

     AR436 

 

 

 

 

 

 

 

 

 

 

            AR433   

 

 

 

    AR434 

 

 

 

 

 

 

 

    

 

 

 

 

WIRELESS SENSORS 

  

  

 

 

 

           

AR437

 

 

                                                               

 

 

Version 1.2.4 

2018-12-07

Summary of Contents for AR431

Page 1: ...yn ul Ga czy skiego 6 Tel 48 22 101 27 31 22 853 48 56 22 853 49 30 fax 48 22 101 27 33 Internet www apar pl email automatyka apar pl USER MANUAL AR431 AR432 AR435 AR436 AR433 AR434 WIRELESS SENSORS A...

Page 2: ...T CONNECTOR IN AR433 434 7 7 CONNECTING TO A COMPUTER AND INSTALLATION OF DRIVERS 7 8 INSTALLATION OF SOFTWARE 8 9 ADDING AND REMOVING MEASUREMENT SENSORS FROM AR407 406 LIST 8 10 SETTING THE CONFIGUR...

Page 3: ...mm spaced at 70x50mm available after removing the front cover or it may be hung using the top 2 holes at the rear of the housing To obtain IP65 the housing cover must be precisely tightened 2 GENERAL...

Page 4: ...high long term stability of measurement accuracy and immunity to interferences compliance with RED directive 2014 53 UE protection against reverse battery insertion available accessories SMA antenna c...

Page 5: ...sion path parameters 4 8 kbit s output power 5 dBm receiver sensitivity 106 dBm range open space 200m maximum 400m with retransmission function in buildings it depends on local conditions antenna SMA...

Page 6: ...and c side view AR431 435 without LCD and LED alarm AR433 without LCD and LED alarm d AR437 1 USB connector for communicating with the computer is inside the housing e external measuring probes For t...

Page 7: ...ecting sensors and measuring signals b connection of 2 and 3 wire transducers Iout current Uout output voltage 7 CONNECTING TO A COMPUTER AND INSTALLATION OF DRIVERS After you connect the device for t...

Page 8: ...he same radio channel number which is different than the number of neighbouring radio networks by default the channel number is 6 the higher numbers are preferred The procedure of adding removing sens...

Page 9: ...y on each device operating in the system sensors and AR407 AR406 recorder 6 3 ID 0 16 D number index 16 sensor off 16 4 RetrID 2 0 3 re transmitter number index 0 retransmission function disabled 0 No...

Page 10: ...RTD sensors and 700 0 00 2 cjte temp of cold ends of thermocouples 20 70 0 C 0 automat automatic 0 C or constant compensation of temperature of the cold junction of thermocouples 0 C automat 3 dot po...

Page 11: ...ible causes of the error exceeding the measuring range of the sensor from above sensor damage attached sensor is different than the one set in configuration chapter 10 3 parameter 1 inp ____ exceeding...

Page 12: ...antenna cable from accessories to avoid obstacles such as walls ceilings furniture etc c 1 change disturbed radio channel in all system devices in each separately to another d 1 consider enabling ret...

Page 13: ...cover and the back wall in its original position Fig 13 1 Disassembly of the rear wall Fig 13 2 Disassembly of the control board AR437 unscrew 4 screws in the front panel and remove them from the devi...

Page 14: ...14 14 USER S NOTES...

Page 15: ...15...

Page 16: ...16...