APACHETA smartLEDs PREMIUM S19-P User Manual Download Page 1

smart

L

E

D

s

                                       

 

 
© APACHETA SMART SYSTEMS 

 

magicstairlighting.com 

 

 

 
 
 
 
 
 
 
 
 

smart

L

E

D

s

 

 

S19-P 

SMART STAIR LED LIGHTING CONTROLLER

 

model PREMIUM 

 
 

USER MANUAL

 

v5.0.6 

 
 

Download  the  full-color  version  of  this  manual  from  magicstairlighting.com,  tab  DOWNLOADS, 
where you will also find a comprehensive guide to installing smart stair LED lighting system. 
 
 
 

 
 
 

 

 

 
In  accordance  with  the  provisions  of  the  Directive  2012/19/EU  on  waste  electrical  and  electronic  equipment  (WEEE)  it  is 
forbidden to place with other waste any waste equipment marked with a crossed-out bin symbol. 
The user, wanting to get rid of electronic equipment or services, is obliged to return it to a waste equipment collection point. 
Applicable  restrictions  have  been  introduced  on  order  to  restrict  the  amount  of  waste  generated  from  waste  electronic 
equipment.  
This equipment does not contain any hazardous ingredients that may have a particularly negative impact on the environment 
and human health. 

Summary of Contents for smartLEDs PREMIUM S19-P

Page 1: ...Directive 2012 19 EU on waste electrical and electronic equipment WEEE it is forbidden to place with other waste any waste equipment marked with a crossed out bin symbol The user wanting to get rid o...

Page 2: ...adually and smoothly The controller can also provide gentle backlight lighting as well as react to motion and dusk S19 P is equipped with built in configurator capable of setting 18 parameters e g bri...

Page 3: ...ed that they are supplied from a DC SELV power supply up to 24 V with a galvanic insulation of the output voltage from the mains supply The maximum current must not exceed 2 A per single output The ou...

Page 4: ...ng on 2 4 2 Lights on When the lights are on they remain on for a time predefined by the On time parameter The time extends when a new signal appears at any of the inputs 2 4 3 Warning When the time d...

Page 5: ...ing by removing the front cover 3 2 2 Restart the controller Restart the controller by pressing the RESET button shortly both signalling diodes RED and GREEN will turn on for about 3 sec 3 2 3 Put con...

Page 6: ...ep in order to repeat all the steps and correct the settings press the SET button briefly under 2 seconds Choose the desired value of the Decision parameter with the and buttons then press and hold th...

Page 7: ...ble lamps the parameter must be set to 0 then there is no backlight lighting and the turning on and off proceeds in a one by one switching fashion 3 4 8 Brigthness The brightness of the LED lamps CAUT...

Page 8: ...witch blocks the controller CAUTION Setting the parameter to one of S1 S10 with the sensor disconnected will result in the controller not being blocked during daylight CAUTION For the built in dusk sw...

Page 9: ...not dimmable turned on together with the first lamp SWITCH BEFORE 2 4 Master not dimmable turned on before the first lamp Number of warnings 0 3 not flashing no warnings 1 3 1 1 warning 2 3 2 2 warni...

Page 10: ...11 90 max brightness 100 8 12 100 max brightness Backlight lighting 0 9 not flashing no backlight lighting 2 9 1 2 brightness 5 9 2 5 brightness 10 9 3 10 brightness 20 9 4 20 brightness 30 9 5 30 bri...

Page 11: ...g on time 9s 12s 12 8 turning on time 12s 18s 12 9 turning on time 18s 24s 12 10 turning on time 24s On time 0s 13 not flashing no lights on phase 4s 13 1 on time 4s 10s 13 2 on time 10s 20s 13 3 on t...

Page 12: ...evel of DIS disables the controller ENABLE 18 1 active level of DIS enables the controller TOGGLE 18 2 active level toggles DIS input S1 18 3 threshold brightness S1 S2 18 4 threshold brightness S2 S3...

Page 13: ...may result in burning of the controller Please ensure that any control device e g motion sensors including those powered with 12V do not apply any voltage onto these inputs CAUTION We advise particul...

Page 14: ...manipulations and changes in the installation with the power off Even a short term occurrence of voltage on the wrong outlet of the controller can permanently damage the controller and such damage is...

Page 15: ...smartLEDs S19 P User manual v5 0 6 APACHETA Smart Systems str 15 15...

Reviews: