Chapter 9: Ventilation and Cooling
the minimum ventilation speed every hour in a linear fashion between consecutive points of the curve.
When the last point is reached, the controller keeps using the speed associated to that day.
The following restrictions apply to reduce the risk of error:
• The highest possible day number is 450.
• Decreasing day numbers are not allowed.
• All ten points must be entered. If you don’t need all ten steps, repeat the last temperature for each
unnecessary points.
NOTE:
The minimum ventilation curve must be turned off to adjust the points and days of the mini-
mum ventilation curve.
Setting the Minimum Ventilation Curve
1. Using the menu select arrow keys, navigate to
Minimum Ventilation / Curve→Variable 1 or Varia-
ble 2→Minimum Curve
.
2. Press the down arrow key to select the first point of the curve.
3. Set the following parameters:
Day
Set the day at which each step starts. The day
number refers to the animal age. *This parameter
can only be modified while the curve is disabled.
Speed
Assign a fan speed to each step of the curve. *This
parameter can only be modified while the curve is
disabled.
Status
Once all 10 curve points are defined, press the
down-arrow key to select the curve status at the
bottom of the screen and then select
Yes
to enable
the curve. Once it is on, the controller automatically
adjusts the minimum ventilation fan speed between
consecutive points of the curve.
Adjusting the Day and Night Minimum Ventilation
1. Using the menu select arrow keys, navigate to
User→Day / Night
.
2. Set the following parameters:
Night Min. Vent
Select
Yes
to use different minimum ventilation set-
tings at night.
Min V1–2
Select the minimum ventilation night speed of each
variable fan (in %).
Setting the Minimum Ventilation Fan Timer
1. Using the menu select arrow keys, navigate to
Minimum Ventilation / Curve→Variable 1 or Varia-
ble 2→Timer/Status
.
2. Set the following parameters:
34
890-00081
Expert VT-110
Summary of Contents for Expert VT-110
Page 1: ...Expert VT 110 User Manual 890 00081 Version 24 REV 19...
Page 6: ...NOTES 6 890 00081 Expert VT 110...
Page 10: ...NOTES 10 890 00081 Expert VT 110...
Page 12: ...NOTES 12 890 00081 Expert VT 110...
Page 22: ...NOTES 22 890 00081 Expert VT 110...
Page 26: ...NOTES 26 890 00081 Expert VT 110...
Page 32: ...NOTES 32 890 00081 Expert VT 110...
Page 46: ...NOTES 46 890 00081 Expert VT 110...
Page 50: ...Chapter 13 Stir Fan 50 890 00081 Expert VT 110...
Page 52: ...NOTES 52 890 00081 Expert VT 110...
Page 64: ...NOTES 64 890 00081 Expert VT 110...
Page 76: ...NOTES 76 890 00081 Expert VT 110...
Page 78: ...NOTES 78 890 00081 Expert VT 110...
Page 79: ...A Worksheets 890 00081 Expert VT 110 79...
Page 80: ...Appendix A Worksheets 80 890 00081 Expert VT 110...
Page 81: ...Appendix A Worksheets 890 00081 Expert VT 110 81...