11
3-BEFORE COMMISSIONING
Warning!
Operating the equipment incorrectly can cause serious injury and
damage. Do not use the functions described here until you have read and
completely understood “safety rules”.
3-1 Utilization for intended purpose only
The power source may only be used for SMAW ,TIG. Utilization for other purposes, or in
any other manner, shall be deemed to be "not in accordance with the intended purpose".
The manufacturer shall not be liable for any damage resulting from such improper
use.Operate, inspect and maintain should follow all the instructions given in this manual.
3-2 Machine installation rules
According to test, protection degree of this power source is IP23S. However, the internal
key components must be protected from direct soaking.
Warning!
A machine that topples over or falls from its stand can cause injury.
Place equipment on an even, firm floor in such a way that it stands firmly.
The venting duct is very important for safety protections. When choosing the machine
location, make sure it is possible for the cooling air to freely enter and exit through the
louvers on the front and back of machine. Any electro conductive metallic dust like
drillings must not be allowed to get sucked into the machine.
3-3 Power source connection
- The power source is designed to run on the voltage given on the nameplate.
- The mains cables and plugs must be mounted in accordance with the relevant
technical standards.
- The power supply sockets that come with power source are designed to use strictly
according to the marked voltages.
Note
!Inadequately dimensioned electrical installations can lead to serious
damage. The mains lead, and its fuse protection, must be dimensioned in accordance
with the local power supply. The technical data shown on the nameplate shall apply.
3-4 Welding cables instruction
When welding, please pay attention to the followings:
a. The welding cables should be kept as short as possible;