Anyload DD-KC1 Instruction Manual Download Page 1

 

Page 1 of 11                                                          Anyload-manual-indicator-DD-KC1-en-101 
 

 
 

      DD-KC1 

          Digital Weight Indicator                   

 

 
 

Instruction Manual 

 
 

 

 
 
 
 

 

www.anyloadgroup.com

 

 
 
 

Summary of Contents for DD-KC1

Page 1: ...Page 1 of 11 Anyload manual indicator DD KC1 en 101 DD KC1 Digital Weight Indicator Instruction Manual www anyloadgroup com...

Page 2: ...t function Go Up on menu or parameters H Tare Enter menu or confirm the change of parameters T 4 Operation Method 4 1 Turn on and off Adapter Insert the plug of AC Adapter into the power supply hub wh...

Page 3: ...he green wire of the indicator s cable Connect SIG with the white wire of the indicator s cable The indicator provides driving voltage through EXC wire and EXC wire SIG wire and SIG wire will transmit...

Page 4: ...until the window displays b Press or button to enter calibration mode c Press button to make sure enter the calibration mode d After entering the calibration mode the window will display Load and 0 0...

Page 5: ...display window keep the platform calm stable and without other interference factors which will influence the weighing performance If the weighing remains stable for more than 2s the scale will finish...

Page 6: ...le so the weight can easily be read a Place the item on the scale platform b Wait for the stable weights to be displayed c Press the key The hold indicators will turn on d Remove the item from the sca...

Page 7: ...ress to confirm and then begin to sample and count f During the process of sampling and counting the screen will display the sampling data by rapidly flickering keep the platform calm stable and witho...

Page 8: ...put Data Display Data Bit Unit Code Ending Code 1 2 3 4 5 6 7 8 9 1 0 11 12 13 123 45kg Blank Blank 1 2 3 4 5 k g Blank CR LF 123 45lb Blank 1 2 3 4 5 l b Blank CR LF 123 0pcs Blank Blank Blank 1 2 3...

Page 9: ...n OFF backlight is turned off Auto backlight is automatic On backlight is turned on 5 OFF Automatic shutdown control no 3 510 15 30 60 min No no automatic shutdown 3 60min if no action of weighing obj...

Page 10: ...indicator and the platform of scale should be kept clean and prevented from corrosion by foreign substance If necessary you should use a piece of cloth with mild washing agent to clean them When you d...

Page 11: ...imensions and specifications subject to change without notice Model DD KC1 Capacity x Readability 3000e Parts counting Standard Repeatability std dev 0 03 Linearity 0 03 T range To capacity by subtrac...

Reviews: