NETWORK GUIDE
SCM-1202-104 1.0 en-US ENGLISH
Page 1: ...A An ny yb bu us s X X g ga at te ew wa ay y P PR RO OF FI IB BU US S M Ma as st te er r I In nt te er rf fa ac ce e NETWORK GUIDE SCM 1202 104 1 0 en US ENGLISH...
Page 2: ...ility or responsibility for any problems that may arise as a result from the use of undocumented features timing or functional side effects found outside the documented scope of this product The effec...
Page 3: ...ument history 3 1 3 Document Conventions 4 1 4 Document specific Conventions 4 2 Description 5 2 1 Overview 5 3 Installation 6 3 1 Connectors and Switches 6 3 2 LED Indicators 7 3 3 Installation Overv...
Page 4: ...This page intentionally left blank...
Page 5: ...ster Interface For additional documentation and software downloads FAQs troubleshooting guides and technical support please visit www anybus com support 1 2 Document history Version Date Description 1...
Page 6: ...s document Document Conventions p 4 This is an external link URL www hms networks com This is additional information which may facilitate installation and or operation This instruction must be followe...
Page 7: ...s Output Buffer Contains data going to the PROFIBUS slaves Fig 1 Data flow The PROFIBUS master interface can exchange up to 512 bytes of I O data in each direction The actual byte sizes of input and o...
Page 8: ...d 5 GND BUS Isolated signal ground RS 485 6 5V BUS 5 V RS 485 7 reserved 8 Line A Negative RS 485 RxD TxD 9 reserved Housing Shield Connected to PE PROFIBUS Configuration Connector X1 2 male 9 pin D s...
Page 9: ...g Network interface error MS Off Offline Green Operating mode Green flashing Clear mode Red Stop mode DB Off No database downloaded Green Database OK Green flashing Database download in process Red Da...
Page 10: ...are optional depending on your actual installation and method of configuration 1 Connect the PROFIBUS master interface to the network 2 Connect a computer to the USB connector 3 Connect a computer to...
Page 11: ...Settings Offline option The action to perform if the network goes offline The gateway can either freeze keep the current value or clear set to zero the data from the offline network Control word Statu...
Page 12: ...S Node Slot Input data size Output data size 0 master 3 1 128 bytes 128 bytes 2 32 bytes 4 1 32 bytes 5 1 32 bytes 2 64 bytes The slave I O addresses overview window in NetTool shows the resulting sla...
Page 13: ...s of the PROFIBUS master interface Slave Input Data Slave Output Data Anybus NetTool for PROFIBUS can be downloaded from www anybus com support where you will also find additional documentation and co...
Page 14: ...the connected slaves Maximum number of slaves 125 Maximum I O data 512 bytes in each direction Supported baud rates Automatic baudrate detection up to 12 Mbit s Configuration method Anybus Configurat...
Page 15: ...This page intentionally left blank...
Page 16: ...last page 2019 HMS Industrial Networks Box 4126 300 04 Halmstad Sweden info hms se SCM 1202 104 1 0 en US 2019 03 06 12169...