![Anybus CompactCom 40 EtherNet/IP Network Manual Download Page 193](http://html1.mh-extra.com/html/anybus/compactcom-40-ethernet-ip/compactcom-40-ethernet-ip_network-manual_2948758193.webp)
Doc.Id. HMSI-27-212
Anybus CompactCom 40 EtherNet/IP
Doc.Rev. 1.5
Appendix E
E. Technical Specification
E.1 Front View
Ethernet Connector
Network Status LED
Note:
A test sequence is performed on this LED during startup.
Module Status LED
Note:
A test sequence is performed on this LED during startup.
LINK/Activity LED 3/4
Ethernet Interface
The Ethernet interface supports 10/100Mbit, full or half duplex operation.
# Item
1 Network Status LED
a
a.
Test sequences are performed on the Network and Module Status LEDs during
startup
2 Module Status LED
3 Link/Activity LED (port 1)
4 Link/Activity LED (port 2)
LED State
Description
Off
No power or no IP address
Green
Online, one or more connections established (CIP Class 1 or 3)
Green, flashing
Online, no connections established
Red
Duplicate IP address, FATAL error
Red, flashing
One or more connections timed out (CIP Class 1 or 3)
LED State
Description
Off
No power
Green
Controlled by a Scanner in Run state
Green, flashing
Not configured, or Scanner in Idle state
Red
Major fault (EXCEPTION-state, FATAL error etc.)
Red, flashing
Recoverable fault(s). Module is configured, but stored parameters differ from currently
used parameters.
LED State
Description
Off
No link, no activity
Green
Link (100 Mbit/s) established
Green, flickering
Activity (100 Mbit/s)
Yellow
Link (10 Mbit/s) established
Yellow, flickering
Activity (10 Mbit/s)
1
2
3
4