![Anybus CompactCom 40 Common Ethernet Design Manual Download Page 13](http://html1.mh-extra.com/html/anybus/compactcom-40-common-ethernet/compactcom-40-common-ethernet_design-manual_2948756013.webp)
11 (104)
3.5
Diagnostics
Events and their severity value are recorded in the Diagnostic Object.
See also...
•
Diagnostic Object (02h), p. 56
3.6
Network Data Exchange
The Anybus CompactCom 40 Common Ethernet does not perform any network specific han-
dling of the process data.
For information on network data exchange for supported networks, please consult the respec-
tive network guides, available at
.
3.7
File System
Category: Extended
3.7.1
Overview
The Anybus CompactCom 40 Common Ethernet has an in-built file system, that can be ac-
cessed from the application and from the network. Three directories are predefined:
VFS
The virtual file system that e.g. holds the web pages of the module. The virtual file
system is enabled by default in the Anybus File System Interface Object (0Ah).
Application
This directory provides access to the application file system through the
Application File System Interface Object (EAh) (optional).
Firmware
Firmware updates are stored in this directory.
In the firmware folder, it is not possible to use append mode when writing a file. Be sure to use
write mode only.
Anybus
®
CompactCom
™
40 Common Ethernet Design Guide
HMSI-27–269 2.1