background image

5

10

8

φ

3.2mm

3.2mm

5 8mm
or less

.

DANGER

WARNING

NOTICE

TC100

LOCK

OUT

AT

AL

1

2

3

4

6

7

9

K

INPUT TYPE

CODE

Pt100

RANGE

( )

RANGE

( )

TC100

LOCK

OUT

AT

AL

MD

MD

MD

LOCK

OUT

AT

AL

LOCK

OUT

AT

AL

1

2

3

1

2

3

ON

DIP Switch

Description

DIP Switch Number

K Type Thermocouple (Default

,

)

Pt100 Type RTD

SSR Output

Relay Output

0.5%  of  F.S.

K Pt100

,

PID ON/OFF

,

35 ~ 85%RH

-10 ~ +50

TC210

TC300

TC400

48Hx48W

96Hx48W

48Hx96W

72Hx72W

96Hx96W

TC100
TC110-10
TC110-11
TC110-20
TC110-21

1

PV
SV

MD

LOCK

AL

OUT

AT

2

3

4

5

6

7

8

9

10

1

2

3

4

-50.0 ~ 400.0

-50 ~ 600

0 ~ 1200

0.0 ~ 400.0

-58.0 ~ 752.0

-58 ~ 1112

0 ~ 2192

0.0 ~ 752.0

TC200

TC100

TC110

TC210

TC300

TC400

TC200

ANV ELECTRIC

PID TEMPERATURE CONTROLLER

MANUAL

Please confirm the specification of controllers is to totally with
your requirement before using it, also read this user's manual
in detail.

D
D

anger! Electric Shock!
on't touch AC power wiring terminal when controller has been

powered!
Keep the power off until all of the wiring are completed!

1. Please confirm the AC power wiring to controller is correc

otherwise it would be caused aggravated damage on
controller

2. Be sure to use the rated power supply(100~240VAC or 24VDC)

otherwise it would be caused aggravated damage on
controller.

3. Please confirm wires are connected with correct terminal

(Input, Output, Alarm).

4. Use M3 screw-compatible crimp-on terminals with an

insulation sleeve, as shown below.

t

TC100/200/210/300/400 with Pin 1,2; TC110  with Pin 7,8)

. (

5. Avoid to install controller in following places:

a. A place where the ambient temperature may reach beyond

the range -10 to 50

.

b. A place where the ambient humidity may reach beyond the

range from 35 to 85% RH.

c. A place where the controller likely to come into contact with

water, oil, chemicals, steam and vapor.

d. A place where the controller is subject to interface with static

electricity, magnetism and noise.

6. For thermocouple(TC) input, use shield compensating lead wire.
7. For RTD input, use shield wires which have low resistance and no

resistance difference between the 3 wires.

8. DIP switch mounts on the PCB, inside the unit. Power off and

detach the case before change setting.

Torque : 0.4 N.m(4kgf.cm)

5 8mm
or less

.

SPECIFICATIONS

INPUT TYPE TABLE

Weight

Ambient Temperature

Ambient Humidity

Power Consumption

Dielectric Strength

Isolated Resistance

Control Algorithms

Electrical Life

Output

Input

Accuracy

Rated Voltage

Dimension(mm)

Model

Voltage Range

100 ~240VAC  50/60Hz  or  24VDC

Rated 90~110%

Relay NO 5A / NC 3A 250VAC

and Voltage DC24V (for SSR drive)

100000 times or more (Under the rated load)

Approx.130g

10M

or more between input terminals

and case(ground) at DC 500V

Ω

1 0 0 0 V A C f o r 1 m i n u t e b e t w e e n i n p u t t e r m i n a l s a n d c a s e ( g r o u n d )

1 5 0 0 V A C f o r 1 m i n u t e b e t w e e n o u t p u t t e r m i n a l s a n d c a s e ( g r o u n d )

Approx.3VA

Approx.3VA

Approx.4VA

Approx.4VA

Approx.4VA

Approx.200g

Approx.200g

Approx.200g

Approx.260g

PARTS DESCRIPTION

SWITCH FUNCTIONS

OPERATIONS

Present Value

Setting Value

Shift Key

SYMBOL

NAME

FUNCTION

Down Key /
Lock Key

Up Key

Mode Key /
Save and Exit Key

Decrease numerals / Press more then
3 seconds to lock key or unlock key

Increase numerals

Shift digits when settings are changed

Use for parameter calling up and
set value registration

Lock Indicator

Alarm Indicator

Output Indicator

Autotuning Indicator

Lights when lock is activated

Lights when alarm is activated

Lights when output is activated

Lights when autotuning is activated

Displays PV

Displays SV

ON

OFF

ON

OFF

ON

ON

OFF

OFF

Select the sensor input
type & control output by
DIP switch on the PCB.

PARAMETER CONFIGURATION (LEVEL 1)

Light all LEDs and all
7 segment displays

Display input type

Display range (0~400.0)

Ready for use

SETTING SV :

Ex: Change SV from 100.0 to 200.0

(Setting without pressing any key over 30 seconds will no save and return to RUN mode)

POWER ON

:

Controller will display as following

Press

key the SV

number started to
flash

Press

key to select

the digits.
Cyclic selection.

Press      key Increase
or Press      key
Decrease value

Press      key save
value and return
to RUN mode

Press      key into the LEVEL 1 parameter configuration.
(Setting without pressing any key over 30 seconds will no save and return to RUN mode)

UPPER LIMIT ALARM :

Press

key to select the digits. Press      key Increase or Press      key Decrease value.

then press      key save value and change to

mode or press      key

3 seconds save value and return to

mode.

LOWER LIMIT ALARM

RUN

Setting range : 0.0 ~ 200.0
Default : 0.0

LOWER LIMIT ALARM :

Setting range : 0.0 ~ 200.0
Default : 0.0

Press

key to select the digits. Press      key Increase or Press      key Decrease value.

then press      key save value and change to

mode or press      key

3 seconds save value and return to

mode.

UPPER ALARM SENSITIVITY

RUN

UPPER ALARM SENSITIVITY :

Setting range : 0.0 ~ 200.0
Default : 0.0

Press

key to select the digits. Press      key Increase or Press      key Decrease value.

then press      key save value and change to

mode or press      key

3 seconds save value and return to

mode.

LOWER ALARM SENSITIVITY

RUN

Setting range : 0.0 ~ 200.0
Default : 0.0

Press

key to select the digits. Press      key Increase or Press      key Decrease value.

then press      key save value and change to

mode

or press      key 3 seconds save value and return to

mode.

INCREASE ON/OFF CONTROL SENSITIVITY

RUN

LOWER ALARM SENSITIVITY :

INCREASE

(PID control mode without this option)

ON/OFF CONTROL SENSITIVITY :

Setting range : 0.0 ~ 200.0
Default : 0.0

Press

key to select the digits. Press      key Increase or Press      key Decrease value.

then press      key save value and change to

mode

or press      key 3 seconds save value and return to

mode.

DECREASE ON/OFF CONTROL SENSITIVITY

RUN

DECREASE ON/OFF CONTROL SENSITIVITY :

(PID control mode without this option)

Setting range : 0.0 ~ 200.0
Default : 0.0

Press

key to select the digits. Press      key Increase or Press      key Decrease value.

then press      key save value and change to

mode or press      key 3 seconds

save value and return to

mode.

AUTO TUNING

RUN

Reviews: