background image

P/N 1011965 Rev A 08/22

6

Operation

Overview

 

y

Normal Operation Mode 

During Normal Operation Mode, 

water enters the Inlet and flows 

through the Filter before exiting the 

outlet as usable product water.

The drain line runs continuously as 

long as the system is making water. 

This drain line flushes the minerals 

removed by the RO membrane.

NOTE:

  DO NOT plug or stop the water 

flow from the drain line. If this 

flow is stopped, water will 

continued to be filtered, but the 

system will not flush. This will 

cause the RO membrane to plug 

prematurely and reduce the life 

of the RO System.

 

y

Tank Full Mode

 

When the tank is full, no water 

runs out of the drain line.

CAUTION

Stopping the drain flow can cause the 

Filter to plug prematurely and may 

reduce the life of the filter. Consult 

the factory for more information.

Figure 1. 

System Components

Figure 2. 

Water Connections

TDS MONITOR

FLUSH VALVE

CHECK VALVE

BLEND VALVE

SOLENOID VALVE

LOW PRESSURE VALVE

BRINE CONTROLLER VALVE

HIGH PRESSURE VALVE

T

T

T

F

B

S

H

BR

F

B

PUMP

S

H

BR

LPS

LPS

PRE-F

IL

TER

CARB

ON

RO

 

MEMB

RANE

PERMEATE

INLET

DRAIN

Summary of Contents for 9710161

Page 1: ...rse Osmosis System Owner s Manual Models AQ RO 400 AQ RO 400 NT AQ RO 600 AQ RO 600 NT Manufacturing Numbers 9710161 9710162 9710163 9710164 www antunes com CAUTION Read all instructions before using the unit Original Instructions ...

Page 2: ...Service at 1 877 392 7854 toll free Fill in the information in the next column and have it handy when calling for assis tance The serial number is on the specifi cation plate located on the system Purchased From Date of Purchase Model Number Serial Number Mfg Number Suggested replacement period for the RO Cartridge is 1 year IMPORTANT This equipment is to be installed to comply with the basic plum...

Page 3: ...lt Protect from direct sunlight or other UV sources Avoid long term exposure to direct sunlight or other UV sources The RO should be stored in a dark location Protect from high temperatures or abrupt variation in temperature The maximum operating temperature is 100 F 38 C Avoid abrupt variations in temperature Any temperature variation should be made slowly Protect from rough handling or dropping ...

Page 4: ... 400 NT Reverse Osmosis Cartridge Single Pack 7002303 AQ RO 600 AQ RO 600 NT Reverse Osmosis Cartridge Single Pack 7002304 Replacement Cartridges CAUTION When installed on metallic plumbing a properly sized electrical bonding jumper must be installed across the inlet and outlet pipes serving this unit CAUTION To ensure proper installation wall anchors for unit must be rated for AT LEAST 60lbs 30 k...

Page 5: ...ximum Operating Temperature 100 F 38 C 100 F 38 C pH Range 4 10 4 10 Maximum Total Dissolved Solids TDS 1 000 ppm 1 000 ppm Maximum Hardness 60 gpg 60 gpg Silt Density Index 5 5 Iron Hydrogen Sulfide or Manganese 0 0 Nominal Capacity 400 600 Membrane performance after 24 hours at 77 F 25 C 500 ppm TDS and 70 psig Membrane performance after 24 hours at 77 F 25 C 500 ppm TDS and 80 psig Performance ...

Page 6: ...nued to be filtered but the system will not flush This will cause the RO membrane to plug prematurely and reduce the life of the RO System y Tank Full Mode When the tank is full no water runs out of the drain line CAUTION Stopping the drain flow can cause the Filter to plug prematurely and may reduce the life of the filter Consult the factory for more information Figure 1 System Components Figure ...

Page 7: ...nstallation The following tools and supplies are sug gested to help with the installation y Screwdriver y Adjustable Wrenches y Drill with Bits y Level y Tape Measure y Pipe Dope or Thread Seal Tape y Two Gallon Bucket y Fresh Unscented Liquid Chlorine Bleach y Pipe Wrenches y Hose or pipe for drain line Mounting the System The RO System comes with a Mounting Bracket for the system When mounting t...

Page 8: ...on the air inlet valve 3 Once the tank air charge is set replace the protective cap on the air valve Drain Connection The drain is for flushing particle buildup out of the system during operation Install a sufficient length of 3 8 OD tubing not supplied from the drain outlet on top of the RO system to the drain When connecting the drain hose pay at tention to the following guidelines y The drain l...

Page 9: ... starts to calculate When the running time is activated on the RO membrane the RO membrane lifetime is based on the calendar time and running time which value is reached first Items Status Filters F1 Prefilter a 10 100 Life Always on b 0 10 Life Symbol Flickering c 0 Life Symbol Off Maintenance IL on Buzz 3 times min F2 Carbon F3 RO Membrane Status PROCESSING a Letter on flickering system flushing...

Page 10: ...the Pre filters and RO Membrane The white sediment prefilter must be installed in the left prefilter housing closest to the water inlet The carbon prefilter must be installed in the right prefilter housing after the sediment prefilter The RO membrane must be installed with the brine seal on the right nearest to the RO membrane housing inlet It should only be inserted into the RO housing from the r...

Page 11: ... and let water into the system 6 Plug the power cord into an outlet The pump will come on and air in the pre filters and RO membrane will come out Wait 5 10 minutes until all air has been removed 7 Adjust the brine control valve so that the pressure gauge is 80 psi Opening the brine control valve increases the brine flow rate and lowers the membrane pressure and product water flow rate 8 Continue ...

Page 12: ...RO The system is now ready for use Maintenance Replacing the RO Cartridge NOTE Always install a new Carbon cartridge after replacing the RO Cartridge 1 Turn off water to the system by closing the feed water valve and unplug the system power cord from the outlet 2 Close the tank valve 3 Depressurize the system 4 Pull out the tube which is inserted into the RO housing s inlet 5 Using the supplied wr...

Page 13: ...rd the date the cartridges where changed and the next change date Replacing the Sediment Prefilter Cartridge NOTE Always install a new Sediment Prefilter Cartridge when replacing the Carbon cartridge 1 Turn off the water to the system by closing the feed water valve 2 Close the tank valve 3 Open a valve on the line to the store to depressurize the system 4 Unscrew the bowl and remove the old sedim...

Page 14: ...lies required Air Pressure Gauge 5 40 psi range 0 3 2 7 bar with tire valve Schrader Valve connection Source of compressed air manual bicycle tire pump or air compressor CAUTION Air pre charge should be checked and adjusted under zero system pressure The system must be depressurized before checking the tank pre Charge Do NOT adjust the tank air pre charge with the system under pressure CAUTION Be ...

Page 15: ... cartridges Storage shipping solution not completely rinsed out of the system Rinse the system for a longer period of time replace carbon cartridges Biological growth in pipes Sanitize plumbing Water conditions changed Consider installing additional filtration Broken membrane in RO Cartridge Replace RO Cartridge Flush runs continuously Tank pressure switch stuck open Replace tank pressure switch W...

Page 16: ...s Exploded View 73 32 32 1 43 51 72 62 21 21 13 24 19 24 13 21 41 41 61 4 23 56 21 57 56 37 18 13 36 13 37 18 46 45 53 53 35 40 54 16 22 48 52 14 16 13 17 27 25 16 13 2 49 63 6 20 31 50 29 30 15 16 26 55 60 21 59 19 20 13 25 40 54 55 38 38 78 74 ...

Page 17: ...ESSURE GAUGE PANEL MOUNTED 1 36 2170212 BLEND VALVE 3 8 TUBE PANEL MOUNTED 1 37 2180495 FILTER BOWL 2 38 2180495 FILTER HEAD 2 39 2180495 FILTER O RING 2 40 2180772 MOUNTING CLIP RO HSG 2 41 2180779 HOUSING BOWL AND HEAD RO 1 42 2180823 GLUE BOX RO CONTROLLER 1 43 2180824 SUPPORT FRAME RO CONTROLLER 1 44 2180825 PLASTIC CLIP M4 x 6 3mm 4 45 2190251 ADAPTOR TUBE TO 1 2 NPT 1 46 2190252 ADAPTOR 1 2 ...

Page 18: ...ure F Feed Pressure psig Product Flowrate ml min Drain Flowrate ml min Percent Recovery Product TDS ppm Feed TDS ppm Percent Rejection Date Date Date Changed Sediment Next Sediment Change Changed Carbon Next Carbon Change Changed RO Next RO Change ...

Page 19: ...P N 1011965 Rev A 08 22 19 Notes ...

Page 20: ...nance calibration or regular adjustments as specified in operating and maintenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations ...