background image

18

®

India Facility

Antunes NADI Manufacturing 

India Pvt. Ltd.

57-58 Thattankulam Road, 

Madhavaram

Chennai, India 600060

Limited Warranty

Equipment manufactured by Antunes) has been constructed of the finest materials available and manufactured 

to high quality standards. These units are warranted to be free from defects in materials and workmanship for a 

period of one year from date of purchase under normal use and service, and when installed in accordance with 

manufacturer’s recommendations*. The ultra filtration membrane cartridge is warranted under the same terms and 

conditions on a prorated basis for 36 months from date of purchase.

*To ensure continued proper operation of the units, follow the maintenance procedure outlined in the Owner’s 

Manual.

1. 

This warranty does not cover failures due to improper system installation, defects caused by improper storage or 

handling prior to placing of the equipment into service. This warranty does not include overtime charges or work 

done by unauthorized service agencies or personnel. This warranty does not cover normal maintenance, calibration, 

or regular adjustments as specified in operating and maintenance instructions of this manual, and/or labor involved 

in moving adjacent objects to gain access to the Equipment. 

2. 

Antunes reserves the right to make changes in design or add any improvements on any product. The right is always 

reserved to modify equipment because of factors beyond our control and government regulations. Changes to 

update equipment DO NOT constitute a warranty charge.

3.  If shipment is damaged in transit, the purchaser should make a claim directly upon the carrier. Careful inspection 

should be made of the shipment as soon as it arrives and visible damage should be noted upon the carrier’s 

documentation. Damage should be reported to the carrier. This damage is not covered under this warranty.

4. 

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED 

OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A 

PARTICULAR PURPOSE, EACH OF WHICH IS HEREBY EXPRESSLY DISCLAIMED. THE REMEDIES 

DESCRIBED ABOVE ARE EXCLUSIVE AND IN NO EVENT SHALL ANTUNES BE LIABLE FOR SPECIAL 

CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR THE BREACH OR DELAY IN PERFORMANCE OF 

THIS WARRANTY.

5. 

Prices and specifications are subject to change without notice.

Summary of Contents for 9710124

Page 1: ...eduction Class I Standard No 53 Health Effects Cyst Reduction Turbidity Reduction as verified and substantiated by test data Owner s Manual Original Instructions Water Filtration Manufacturing Numbers 9710124 9710125 9710126 UFL 510 UFL 520 UFL 540 www antunes com CAUTION Read all instructions before using the unit Original Instructions P N 1012043 Rev B 11 19 ...

Page 2: ...should be read prior to installing and operating the system Your UFL system is manufactured from the finest materials available and is assembled to strict quality standards This system has been tested at the factory to ensure dependable trouble free operation In Case of Damage If the unit arrives damaged file a claim with the carrier immediately Save all packing materials when filing a claim Freig...

Page 3: ...suitably sized booster system outlet pressure 60 psig 100 psig max 414 kPa 690 kPa max be installed WARNING ELECTRICAL SHOCK HAZARD Failure to follow the instructions in this manual could result in serious injury or death DO NOT modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by a qualified electrician DO NOT use an extension cord with this unit If th...

Page 4: ...ng solutions insecticides Protect from abrasive material The membranes must be protected from abrasive materials like shavings left in a pipe Abrasive materials in contact with the membrane can cause irreversible damage to the membrane All pipes must be flushed clean before installing the filter All plastic parts of the filter system must be protected from sharp objects like knives sand paper or o...

Page 5: ... 08 50 60 Electrical Cord Plug Configurations Kit Model Number Description Configuration Kit 0012146 DC Power Supply 100 240 VAC Includes the 4 plug adaptors below US NEMA 1 15 2 pin or NEMA 5 15 3 Pin Euro CEE 7 16 AS NZS 3112 AUS 2 Pin UK BS 1363 NOTE Includes plug adaptors for US Europe Australia and UK NOTE PLUG STYLE MAY VARY US NEMA 1 15 2 PIN or NEMA 5 15 3 PIN EURO CEE 7 16 AS NZS 3112 2 P...

Page 6: ...SF ANSI 42 or 53 While testing was performed under standard laboratory conditions actual performance may vary DO NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts Filter Cartridge Capacities Maximum Operating Press...

Page 7: ...ltered but the system will NOT flush This could cause the UltraFilter to plug prematurely and may reduce the life of the filter Manual Flushing A manual flush can be activated at any time by pressing the FLUSH button on the Universal Pulse Controller When the FLUSH button is pressed the Flush LED on the controller flashes and the Drain Valve opens for 10 seconds After flushing is complete the Drai...

Page 8: ...d electrical outlet Plumbing NOTE The system must be connected to the COLD water line DO NOT connect the system to the hot water line The UFL system uses the following connections System Inlet 3 4 FNPT System Outlet Product Water 3 4 FNPT Drain 3 4 FNPT When making a plumbing connection to the system use a back up wrench on the supporting plumbing Always use a quality approved pipe sealant or thre...

Page 9: ...he system near a drain for flushing operations y y Mount the system before all consumable water filtration processes y y Secure the Mounting Bracket provided with the UFL system into wall studs with heavy duty hardware capable of supporting 120lbs Or more Mounting Hardware Not Supplied y y Mount the UFL system to the Mounting Bracket and secure with heavy duty hardware Mounting Hardware Not Suppli...

Page 10: ... When connecting the drain hose pay attention to the following guidelines y y The drain line plumbing must be able support the flow rate whenever the system flushes This flow rate is dependent on the inlet water pressure inlet pipe size and system y y The drain line leading out of the system must be as short as possible and slope downwards without any kinks or loops y y The drain line plumbing mus...

Page 11: ... Flush LED will stop flashing and one or more LEDs will remain lit indicating the unit has power and which interval is selected in the controller Water Flow Water Flow Tee Inlet Ball Valve Manual Outlet Fully Ported Ball Valve Fully Ported Ball Valve System Inlet Connection The System Inlet has a 3 4 FNPT thread at the Inlet Valve Figure 6 DO NOT overtighten fittings as this could cause the plasti...

Page 12: ...minutes without water flow open the faucet or tap 12 Allow water to flow through the system until the presence of sanitizer is gone 13 Open all other faucets and taps in line with the system to flush any remaining sanitizer from the plumbing 14 Close all faucets and taps Rinsing the UltraFilter Cartridge The UltraFilter Cartridge comes pre installed in the UFL system The UltraFilter Cartridge must...

Page 13: ... 7 Lubricate all O rings with a food grade silicone lubricant Apply a light coating of lubricant to the inside center tube at both ends of the new cartridge 8 Position the new cartridge into the housing and gently insert into the housing 9 Ensure the cartridge is fully seated on the opposite end cap 10 Press the End Cap into position until it is fully seated 11 Install the UltraFilter Housing clam...

Page 14: ...r can be reset Unplug the power supply wait for 5 seconds and then plug the power supply in When power is restored to the controller it will automatically enter Flush Mode The controller will then begin timing from the point when power is restored based on the interval setting selected Flush Interval Button Hold Time Button LED Flush LED 15 minutes A 10 seconds On On 30 minutes B 10 seconds On On ...

Page 15: ...ctive Clean or replace the outlet check valve assembly The inlet flow restrictor may be plugged Clean or replace the inlet flow restrictor Water tastes bad Storage shipping solution not completely rinsed out of the system Rinse the system for a longer period of time Biological growth in pipes Sanitize plumbing Water condition changed Consider installing additional filtration Broken capillaries in ...

Page 16: ...LVE SOL NC 24VDC 3 4 NPT 1 10 7001576 Universal Pulse Controller 1 11 7001914 O Ring Kit End Cap 4 12 7001915 L 410 Cartridge UFL 510 ONLY 7001917 L 420 Cartridge UFL 520 ONLY 7001916 L 410 Cartridge UFL 540 ONLY 1 13 7002014 End Cap Kit SS Drain 1 14 7002015 Clamp Kit 4 SS UF Housing 2 15 7002016 Clamp Kit UFL Housing 2 16 7002017 Rubber Cradle Kit SS Housing 2 17 7002057 Kit UFL 510 5 GPM End Ca...

Page 17: ...UFL 500 SERIES 17 P N 1012043 Rev B 11 19 Exploded View UFL 510 UFL 520 and UFL 540 Systems 5 6 3 2 7 8 7 10 2 7 8 7 9 13 14 16 11 16 15 15 12 17 11 14 4 1 ...

Page 18: ...intenance calibration or regular adjustments as specified in operating and maintenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulati...