Antunes Controls G Installation Information Download Page 1

WARNING

Read these instructions carefully before attempting to install, operate or service this
switch.

Failure to observe safety information and comply with instructions could result in
personal injury, death and/or property damage.

To avoid electrical shock or damage to equipment, disconnect power before installing
or servicing.

To avoid potential fire and/or explosion, do not use in potentially flammable or
explosive atmosphere.

Retain these instructions for future reference. You must review your application and
national and local codes to ensure that your installation will be functional and safe.

GGI 1010810019

Page 1

Printed in USA 0700

MODEL - G

Gas Pressure Switches

INSTALLATION INFORMATION

GENERAL INFORMATION

You are installing one of the finest gas pressure
switches of its type on the market. Design of
these switches is based on the same principles
of sensitivity, accuracy and dependability that
have made Antunes Controls Air Flow Switches
so successful. These switches are fully
approved. They are C-UL listed and recognized
for the U.S. and Canada, approved by Factory
Mutual (FM).

Antunes Controls Gas Pressure Switches moni-
tor gas pressure. The models are available in
high pressure and low pressure single gas
switches. Pressure range varies from .5" of
water column to 4 psi.

Each switch is adjustable within its range, as
shown on the range scale located on top of the
unit. The latch button in the reset models, and
the optional neon light in the recycle models,
show whether the switch is on or off.

The Model G is sturdy, compact and cost
effective. All components are well made.

The switch is neat in appearance with its durable
plastic electrical housing and die cast aluminum
base. In every way you will be pleased with the
ease of installation and the reliability of Antunes
Controls Gas Pressure Switches.

Please read these instructions carefully to
ensure correct installation. This equipment must
be installed by a licensed electrician who is
experienced with combustion safeguard control
systems and understands the functions of inter-
locking switches such as air and gas pressure
switches. Prior to being put into operation with
combustion safeguard systems, all switches
should be tested for proper range setting and
wiring. Check piping connections and switch
housing for leaks with a soap bubble test. All
exhaust fans and blowers should be inspected
and checked for proper rotation prior to start up.
If you have any problems or questions, phone,
fax or write to Antunes Controls at the numbers
listed on the back page of this instruction sheet.

Summary of Contents for G

Page 1: ...n high pressure and low pressure single gas switches Pressure range varies from 5 of water column to 4 psi Each switch is adjustable within its range as shown on the range scale located on top of the unit The latch button in the reset models and the optional neon light in the recycle models show whether the switch is on or off The Model G is sturdy compact and cost effective All components are wel...

Page 2: ...pplied To Switch COM P NO NC Diagram Shows Pressure Being Applied To Switch LOW PRESSURE When pressure decreases below setpoint NO opens NC closes HIGH PRESSURE When pressure increases above setpoint NO closes NC opens COM Ground NO NC 1 2 Conduit Nut Connect to Common COM 1 2 Conduit Attach 1 2 Conduit Fitting to Switch with 1 2 Conduit Nut Depending on Switch Operation Connect to Normally OPEN N...

Page 3: ...ow the cover the unit is on not latched If the yellow ring is above the cover the unit is off latched The yellow ring must be below the cover after latching to be properly set High Gas Pressure Models High gas pressure switches break the electrical circuit when pressure rises above the indicated preset pres sure The yellow ring will be below the cover indicat ing that the switch is on when the gas...

Page 4: ...ed for the equipment is a con sideration in limiting seller s liability No action regardless of form arising out of the transactions may be brought by purchaser more than one year after the cause of action has accrued 180 KEHOE BLVD CAROL STREAM IL 60188 USA 1 800 253 2991 www antunescontrols com TEMPERATURE CONTROLLERS TEMPERATURE DISPLAYS AIR PRESSURE SWITCHES GAS SWITCHES CUSTOM ELECTRONIC CONT...