background image

Antona Corporation   (818)783-4299 http://www.antona.com

4

Serial Port Interface

The clock contains a double buffered UART (universal asynchronous receiver

transmitter) that will decode a fixed format message at 2400 Baud, 8-data bits, no parity
and 1-stop bit.  The physical interface is both RS422 and RS485 compatible providing
differential noise immune operation at up to a 4,000 foot distance.  Currently, 8 clock
addresses are supported, but up 32 clocks can be driven with from the ANC-7030.  The
current version of software in the ANC-7030 controller sends out dim/brightness data to
clocks 0,1,2 and 3 only to reduce the refresh cycle at each clock to 4-seconds.  See
appendix A for the protocol of the serial data.

Clock Display and Error Messages

  Most of the time the four LED digits will display time-of-day in 24-hour format.  At
midnight, the display rolls over from "23:59" to "00:00".  All ANC-7020 clock displays
connected to the ANC-7030 controller will update the time change to the display
simultaneously on the minute.

  If there is no clock signal being received, the clock will display "

Sync

" to indicate that

no-

sync

hronization time signal has been received in 1.1 second.  Check that the power

is on at the ANC-7030 clock controller unit, and that the RJ-11 connector cable in the
back of the chassis is plugged into the adapter over the DB-9 labeled "CLOCK".  If that
does not solve the problem, check the individual cable runs into and out of each clock.

  A display of "

3?:??

" indicates that time data is being received, the data is just not in

range (over 23:59).  This could be caused by a failure on the ANC-7332 clock I/O card
due to a real time clock chip failure or the clock I/O card (ANC-7332).  Most likely, the
battery that runs the clock chip in the ANC-7030 chassis when power is off, has been
exhausted, and should be replaced (and the time reset from the front panel).

Clock Jumper Options

Before opening the clock case remove power to the enclosure by pulling the left

hand lower side barrel connector from the aluminum case.  To open the enclosure to
change jumper options use a small flat blade screwdriver and carefully remove the 4
black nylon screws from the corners of the front blue plastic filter.  

The plastic filter

will only go on one way so note side and orientation when the filter is removed
for easiest reassembly when finished

.  To change jumper options near the

microprocessor, remove the 10s of hour digit by carefully pulling up on the digit and
removing it from the aluminum clock case.
  Reassemble the enclosure by first reinstalling the 10s of hour digit (if removed) by
lining up the gold pins on the clock motherboard with the mating black receptacle on
the 5X7 LED display along the vertically running 7-pin single inline connector.  Once
the vertical connector is seated, press down on the 5X7 matrix along the top of the
display to seat the horizontally running 7-pin connector.  Plug power back into the clock
at this point to insure that the 10s digit is operating correctly, and that any jumper
options changed are working.  Lastly, use the black nylon screws to replace the front
blue plastic panel.  The black nylon screws should 

easily

 reassemble if the blue plastic

filter is oriented properly.

Summary of Contents for ANC-7020 Series

Page 1: ...Antona Corporation 818 783 4299 URL http www antona com 1 Rev A ANC 7020 Series RS 485 RS 422 Synchronous Clock Display Antona Corporation Los Angeles CA Antona Corporation Los Angeles CA ...

Page 2: ...e to the effects of static electricity discharge In no event shall Antona Corporation be liable to the purchaser for loss of use profit or consequential damages or damages of any kind including but not limited to accidental loss or damage to other equipment arising out of use of Antona Corporation equipment whether or not said equipment was used properly The designer is responsible for the determi...

Page 3: ...LECTRICALSPECIFICATIONS 3 INSTALLATION 3 SERIAL PORT INTERFACE 4 CLOCK DISPLAY ANDERROR MESSAGES 4 CLOCK JUMPER OPTIONS 4 Software Options 5 CLOCK SERIAL INTERFACE TERMINATION 6 EXTERNAL CONNECTIONS TO ANC 7020 6 RS422 RS485 SIGNALS 6 POWER SUPPLY CONNECTOR 7 APPENDIX A CLOCK PROTOCOL 8 APPENDIX B CIRCUIT BOARD SCHEMATIC 9 ...

Page 4: ...Connectors 6 pin RJ 11 modular phone jack with loop through 2 1mm Barrel connector for 5V DC power to unit center pos Electrical Specifications Power requirements 180 ma for full brightness and all LEDs on 150 ma for display at full brightness and normal time display 30 ma for display at dimmest setting and normal time display 20 ma for display off 0 16 brightness setting RS 422 485 input short pr...

Page 5: ...eived the data is just not in range over 23 59 This could be caused by a failure on the ANC 7332 clock I O card due to a real time clock chip failure or the clock I O card ANC 7332 Most likely the battery that runs the clock chip in the ANC 7030 chassis when power is off has been exhausted and should be replaced and the time reset from the front panel Clock Jumper Options Before opening the clock ...

Page 6: ...t is blanked when a time of day display is less than 10 00 When enabled this would display 6 00 on the unit instead of 06 00 Jumpers 6 and 7 are not installed when shipped unless the customer has requested such options Figure 1 Jumper pin Function shunt on 0 not used 1 Address bit 0 2 Address bit 1 3 Address bit 2 4 not used 5 not used 6 Blink Colon on input 7 Leading zero Suppression Table 1 Cloc...

Page 7: ...these jumpers have been installed across the two jumper pins External connections to ANC 7020 There are three external connectors on the left hand side panel of the display Two of the connectors are 6 pin RJ 11 modular phone type receptacles All 6 contacts are connected in parallel on each connector This means that either receptacle may be used to input the drive signal and loop through another ca...

Page 8: ...nt is 200 ma and the center conductor of the barrel connector is plus voltage 5v Use the supplied external wall type DC source to plug into this connector For an overall brighter display at all brightness settings up to a 9V DC power supply may be used An internal 5V regulator handles the step down for the microcontroller and associated circuitry when the applied DC voltage is higher than 5V ...

Page 9: ...smission Data whether time or control information is fixed at 6 bytes as follows Byte Description 1 Sync Code CCH 2 Unit Address 00H to 08H All 80H 3 Control Code 4 Data byte 1 hours brightness 5 Data byte 2 minutes 6 Checksum sum of bytes 2 5 modulo 8 1 s compliment the control codes are as follows 21H set clock time of day with bytes 4 5 packed BCD 20H set clock brightness with byte 4 lower nibb...

Page 10: ...wing page s contain the schematic for the series 7020 time of day clock display The schematic and card artwork are copyright protected by Antona Corporation and are included only to aid the end user to configure the adapter or for competent technical service personnel to use in maintenance or repair ...

Page 11: ...Antona Corporation 818 783 4299 http www antona com 10 ...

Reviews: