background image

Antaira Technologies - Industrial Ethernet Switches 

LNX-1002C-SFP series User Manual V1.0 

 

 

 

 

 

 

LNX-1002C-SFP Series

 

10-Port Industrial Unmanaged Ethernet Switches, with 

8*10/100Tx and 2* Gigabit Combo Ports (2*10/100/1000Tx RJ45, 

and 2*100/1000 SFP Slots) 

 

 

 

 

 

 

 

 

 

 

User Manual 

Version 1.0 

 

 

 

 

Summary of Contents for LNX-1002C-SFP Series

Page 1: ...hernet Switches LNX 1002C SFP series User Manual V1 0 i LNX 1002C SFP Series 10 Port Industrial Unmanaged Ethernet Switches with 8 10 100Tx and 2 Gigabit Combo Ports 2 10 100 1000Tx RJ45 and 2 100 1000 SFP Slots User Manual Version 1 0 ...

Page 2: ...rs Notice Copyrights 2015 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the copyright laws Disclaimer Antaira Technologies LLC provides this manual without warranty of any kind expressed or implied including but not limited to the implied warranties of merchantability...

Page 3: ...to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution Any changes or modifications not expressly ...

Page 4: ...al Dimensions 3 2 2 Front Panel 4 2 3 Top View 4 2 4 LED Indicators 5 2 5 Ethernet Ports 6 2 6 Cabling 8 2 6 1 Gigabit Combo Port Copper SFP Mini GBIC 8 2 7 Wiring the Power Inputs 11 2 8 Wiring the Fault Alarm Contact 12 3 Mounting Installation 13 3 1 DIN Rail Mounting 13 3 2 Wall Mounting 15 4 Hardware Installation 16 4 1 Installation Steps 16 5 Network Application 17 6 Trouble Shooting 18 7 Tec...

Page 5: ...warning function alerts maintainers when power failures occur The LNX 1002C SFP series includes two models one with an operating temperature range of 10 to 70 C and the other with an extended operating temperature range of 40 to 75 C This product series has been designed to fulfill special needs for industrial automation and harsh outdoor environment applications 1 1 Key Features System Interface ...

Page 6: ...00 1000Tx RJ45 and 2 100 1000 SFP slots 1 User manual 1 Product CD 2 Wall mounting brackets and screws 1 DC cable 18 AWG DC jack 5 5x2 1mm 1 3 Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be described wit...

Page 7: ...hysical Dimensions Figure 2 1 below shows the physical dimensions of Antaira Technologies LNX 1002C SFP series 10 port industrial unmanaged switch with 8 10 100Tx and 2 Gigabit combo ports 2 10 100 1000Tx RJ45 and 2 100 1000 SFP slots W x D x H is 46mm x 99mm x 142mm Figure 2 1 LNX 1002C SFP Series Physical Dimensions ...

Page 8: ...ne 6 pin removal terminal block connector for dual DC power inputs 12 48VDC Figure 2 2 Front Panel of the LNX 1002C SFP Series Figure 2 3 Top Panel View of LNX 1002C SFP Series 6 Pin Removal Terminal Block Power Input LED for PWR1 PWR2 and Fault Gigabit Combo Port G2 100 1000 SFP Gigabit Combo Port G1 100 1000 SFP LED for G1 G2 SFP Fiber Ports LED for Ethernet Port Status Gigabit Combo Port G1 10 ...

Page 9: ... inputs ports link is active port alarm is disabled LAN Port 1 8 Upper LED Green On Connected to network 100Mbps Flashing Networking is active Off Not connected to network LAN Port 1 8 Lower LED Green On Connected to network 10Mbps Flashing Networking is active Off Not connected to network Gigabit Combo Port LED Indicators LED Color Description SFP Port Combo G1 G2 LNK ACT Green 1000Mbps On Connec...

Page 10: ...Tx All ports on this industrial Ethernet switch support automatic MDI MDI X operations Users can use straight through cables see figure below for all network connections to PCs servers and other switches or hubs With straight through cabling pins 1 2 3 and 6 are at one end of the cable and are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below Table 2 3 sh...

Page 11: ...ing schematics for straight through and crossover cables The following figures show the 10 and 100 Ethernet RJ 45 pin outs Figure 2 7 Straight Through Cables Schematic Figure 2 8 Crossover Cables Schematic Figure 2 6 RJ45 Ethernet Port Pin Outs Figure 2 4 Straight Through Cables Schematic Figure 2 5 Crossover Cables Schematic ...

Page 12: ...ransceiver used in optical communications for both telecommunication and data communications The SFP slots support dual rate mode which can switch the connection speed between 100 and 1000Mbps They are used for connecting to the network segment with a single or multi mode fiber Users must first choose the appropriate SFP transceiver to plug into the slots and then choose the proper multi mode or s...

Page 13: ...ver and LC cable please follow the steps below First insert the SFP transceiver module into the SFP slot as shown below in Figure 2 9 Notice that the triangle mark is at the bottom of the SFP slot Figure 2 10 shows that the SFP transceiver module has been inserted Second insert the fiber cable of the LC connector into the transceiver as shown in Figure 2 11 Figure 2 9 Transceiver to the SFP Module...

Page 14: ...r please follow the steps shown below 1 Press the upper side of the LC connector from the transceiver and pull it out to release as shown below in Figure 2 12 2 Push down the metal clasp and pull the transceiver out by the plastic part as shown below in Figure 2 13 Figure 2 12 Remove LC Connector Figure 2 13 Pull Out from the SFP Module ...

Page 15: ...tive wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 14 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 15 Note Only use copper conductors 60 75 C tighten to 5 lbs The wire gauge for the terminal block should range between 18 20 AWG Figure 2 15 Power Terminal Block Figure 2 14 Power Terminal...

Page 16: ...re 2 16 By inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch only and form a normal open circuit An example is shown below in Figure 2 16 Note The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate the power fault alarm Figure 2...

Page 17: ...tallation 3 1 DIN Rail Mounting The DIN Rail is pre installed on the industrial Ethernet switch from the factory If the DIN Rail is not on the industrial Ethernet switch please refer to Figure 3 1 to learn how to install the DIN Rail on the switch Figure 3 1 The Rear Side of the Switch and DIN Rail Bracket ...

Page 18: ...racket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figure 3 2 4 Lightly pull down the bracket on to the rail as shown below in Figure 3 3 5 Check if the bracket is mounted tightly on the rail 6 To remove the industrial Ethernet switch from the rail do the opposite from the abov...

Page 19: ... Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall 5 To remove the wall mount bracket do the opposite from the steps above Below in Figure 3 5 are the dimensio...

Page 20: ...ing section for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power Inputs section Please refer to the LED Indicators section for LED light indication 5 ...

Page 21: ...l Ethernet Switches LNX 1002C SFP Series User Manual V1 0 17 5 Network Application This segment provides an example of an industrial Ethernet switch application Figure 5 1 Figure 5 1 Industrial Ethernet Switch Application Reference ...

Page 22: ...feet Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist o Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose power connections p...

Page 23: ...net Port Transmission Distance Up to 100M Transmission Speed Up to 1000Mbps MAC Address 8K Table Size RJ45 Ethernet Port 8 10 100Tx 2 10 100 1000Tx Gigabit Combo auto negotiation speed full half duplex mode and auto MDI MDI X connection SFP Slot 2 100 1000 dual rate SFP for Fiber Gigabit Combo LED Power Unit P1 Green P2 Green Fault Red Ethernet port Link active Green SFP Link active Green Network ...

Page 24: ...lass A CE EN61000 4 2 3 4 5 6 8 CE EN61000 6 2 CE EN61000 6 4 Stability Testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration Safety UL 508 Pending Table 7 1 LNX 1002C SFP Series Technical Specifications Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems t...

Reviews:

Related manuals for LNX-1002C-SFP Series