background image

Antaira Technologies - Industrial Ethernet Switches 

LNP-0802-24 Series User Manual V2.1 

 

 

 

 

 

 

LNP-0802-24 Series

 

8-Port Industrial PoE+ Unmanaged Ethernet Switches with 

6*10/100Tx (30W/Port) + 2*10/100Tx   

 

 

 

 

 

 

 

 

 

 

User Manual 

Version 2.1 

 

 

 

Summary of Contents for LNP-0802-24 Series

Page 1: ... Technologies Industrial Ethernet Switches LNP 0802 24 Series User Manual V2 1 i LNP 0802 24 Series 8 Port Industrial PoE Unmanaged Ethernet Switches with 6 10 100Tx 30W Port 2 10 100Tx User Manual Version 2 1 ...

Page 2: ...s Notice Copyrights 2018 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the copyright laws Disclaimer Antaira Technologies LLC provides this manual without warranty of any kind expressed or implied including but not limited to the implied warranties of merchantability ...

Page 3: ...of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution Any changes or modifications not expressly approved by the grantee of this device could void ...

Page 4: ...Description 3 2 1 Physical Dimensions 3 2 2 Front Panel 4 2 3 Top View 4 2 4 LED Indicators 5 2 5 Ethernet Ports 6 2 6 Cabling 8 2 7 Wiring the Power Inputs 8 2 8 Wiring the Fault Alarm Contact 9 3 Mounting Installation 10 3 1 DIN Rail Mounting 10 3 2 Wall Mounting 11 4 Hardware Installation 12 4 1 Installation Steps 12 5 Network Application 13 6 Trouble Shooting 13 7 Technical Specifications 15 ...

Page 5: ...TD 10 C to 70 C or an extended temperature range EOT 40 C to 75 C It also provides Ethernet connectivity with PoE functions and a fiber connection for outdoor or harsh industrial automation application environments such as security surveillance ITS traffic monitoring systems oil gas and mining facility management for power utility water wastewater treatment plants and lastly automated production l...

Page 6: ...type connector Multi mode 2Km or Single mode 30Km 1 User manual 1 Product CD 2 Wall mounting brackets and screws 1 DC cable 18 AWG DC jack 5 5x2 1mm 1 3 Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be des...

Page 7: ...Dimensions Figure 2 1 below shows the physical dimensions of Antaira Technologies LNP 0802 24 series 8 port industrial PoE unmanaged Ethernet switch with 6 10 100Tx 30W port 2 100Fx Fiber SC ST type connector Multi mode 2Km or Single mode 30Km W x D x H is 46mm x 99mm x 142mm Figure 2 1 LNP 0802 24 Series Physical Dimensions ...

Page 8: ...op View Figure 2 3 below shows the top panel of the LNP 0802 24 series switch that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 12 36 VDC Figure 2 2 Front Panel of the LNP 0802 24 Series Figure 2 3 Top Panel View of LNP 0802 24 Series 6 Pin Removal Terminal Block Power Input Grounding Screw LED for PWR1 PWR2 and Fault Fiber Port 7 8 100Fx Tx Rx LED for Fiber...

Page 9: ...tive Off Power input 2 is inactive Fault Red On Power input 1 or 2 is inactive Off Power input 1 and 2 are both functional or no power inputs PoE Indicators Port 1 6 Green On The port is supplying PoE power Off No powered device attached or power supplying fails LAN Port 1 6 Upper LED Green On Connected to network 100Mbps Flashing Networking is active Off Not connected to network LAN Port 1 6 Lowe...

Page 10: ...pport automatic MDI MDI X operations Users can use straight through cables see figure below for all network connections to PCs servers and other switches or hubs With straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below Table 2 3 shows the 10BASE T 100BASE TX 1000BASE T MDI and MDI X port pi...

Page 11: ... type connector can work in multi mode or single mode When connecting the fiber port to another one please connect accordingly by following the figure below The wrong connection will cause the port to not work normally ATTENTION This is a Class 1 Laser LED product Don t stare into the Laser LED beam Figure 2 4 Straight Through Cables Schematic Figure 2 5 Crossover Cables Schematic Figure 2 6 Fiber...

Page 12: ...r type must use 9 125μm single mode fiber cable Fiber segment using multi mode connector type must use 50 or 62 5 125 μm multi mode fiber cable 2 7 Wiring the Power Inputs Please follow the below steps to insert the power wire 1 Insert the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 7 2 Tighten the wire clamp sc...

Page 13: ...gure 2 9 By inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch only and form a normal open circuit An example is shown below in Figure 2 9 Note The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault alarm Figure 2 9 W...

Page 14: ...l the DIN Rail bracket on the rear side of the industrial Ethernet switch 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figure 3 2 4 Lightly pull down the bracket on to the rail as shown below in Figure 3 3 5 Check if the bracket is mounted tightl...

Page 15: ...Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall 5 To remove the wall mount bracket do the opposite from the steps above Below in Figure 3 5 are the dimension...

Page 16: ... to the Wall Mounting section for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on For the help on how to wire power please refer to the Wiring the Power Inputs section Please refer to the LED Indicators section for LED light...

Page 17: ... Switches LNP 0802 24 Series User Manual V2 1 13 5 Network Application This segment provides an example of an industrial Ethernet switch application Figure 5 1 6 Trouble Shooting Figure 5 1 Industrial PoE Ethernet Switch Application Reference ...

Page 18: ...8 feet Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist o Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose power connections...

Page 19: ...speed Full Half duplex mode and auto MDI MDI X connection PoE Pin Assignment V V V V for pin 1 2 3 6 Endspan MDI Alternative A Fiber Port 2 100Fx SC ST Multi mode 2Km Single mode 30Km Network Cable 10BaseT 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100BaseTX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m 1000BaseTX UTP STP Cat 5 5E cable EIA TIA 568 100 ohm 100m Protection Overlo...

Page 20: ... Approvals EMI FCC Class A EMS IEC6100 4 2 3 4 5 6 8 IEC6100 6 2 IEC6100 6 4 Stability Testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration Safety UL 508 UL Class 1 Division 2 ISA 12 12 01 Table 7 1 LNP 0802 24 Series Technical Specifications Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 ...

Reviews: