6
Antaira Technologies - Industrial Ethernet Switches
LMX-0800 Series Hardware Manual V1.3
2.4 LED Indicators
There are LED light indicators located on the front panel of the industrial Ethernet switch that
display the power status and network status. Each LED indicator has a different color and
has its own specific meaning, see below in Table 2.1.
LED
Color
Description
P1
Green
On
Power input 1 is active
Off
Power input 1 is inactive
P2
Green
On
Power input 2 is active
Off
Power input 2 is inactive
Fault
Red
On
Fault has been triggered by a configured event (ex.
Port 7 link broken)
Off
Power input 1 and 2 are both functional, or no power,
inputs/ports link is active/port alarm is disabled
Owner
Green
On
ERPS Owner Mode (Ring Master) is ready
Off
ERPS Owner Mode is not active
Ring
Green
On
Ring Network is active
Off
Ring Network is not active
LAN Port 1 ~ 8
(Left LED)
Green
On
Connected to network, 10/100Mbps
Flashing Networking is active
Off
Not connected to network
Table 2.1 - LED Indicators for LMX-0800 Series
Caution: "P1" is the abbreviation for "Power ", “P2” is for “Power 2”, “LNK” is for “Link”, and "ACT" is for
"Activity".
2.5 Reset Button
There is a ‘Reset’ button located on the front panel of the industrial Ethernet switch that helps
users to reboot, restore default, or save running configurations by pressing the button for
different seconds. Please refer to Table 2.2 for the timing and function.
Seconds
Function
1
Save running configuration to USB
4-6
Reboot the switch
7 or more
Restore factory default
Table 2.2 – Reset Button Functions