Antaira Technologies - Industrial Ethernet Switches
LMP-1600G-M12-67-24 Series - Hardware Manual - v1.0.1
2.7 Console Port
●
It is an M12 5-Pin A-Coded female connector
●
Baud rate 115, 200bps, 8, N, 1
●
M12 connector
M12 5-Pin A-Coded female connector
Pinouts
Function
1
NC
2
TX
3
RX
4
NC
5
GND
Table 2.4 - Console port pinouts
2.8 Power Inputs
This industrial Ethernet switch provides dual DC power inputs for redundancy through the M12 5-pin K-Coded male
connector. Prepare the M12 5-pin K-Coded cable for power connection.
Table 2.5
shows the pin assignment.
M12 5-Pin K-Coded Male Connector
Pinouts
Function
1
V1+
2
V1-
3
V2-
4
V2+
5
GND
Table 2.5 - Power input pinouts
●
Connection of Cables
○
Minimum Wire Gauge: 18AWG
Please follow the steps below to insert the power wire.
Step 1: Insert the positive and negative power wires into the power connector on the industrial Ethernet switch with Power
1 (V1+, V1-), and Power 2 (V2+, V2-).
Step 2: Tighten the screw nut to prevent the connector from loosening.