vii
Antaira Technologies - Industrial Ethernet Switches
LMP-1202M-SFP Series Hardware Manual V1.0
Supports IPv4/IPv6, RMON, MIB II, port mirroring, event syslog, DNS, NTP/SNTP,
HTTPS, SSH/SSL, TFTP
MODBUS TCP for SCADA system integration
Port Configuration
Status, statistics, mirroring, rate limiting, event syslog
Event Handling
Event notification by Email: Cold/Warm Start, Power Failure, Authentication, SNMP
trap and Fault Alarm Relay Output
Software Upgrade via TFTP and HTTP
Configuration Backup – USB Port
1.3 Product Hardware Features
System Interface and Performance
•
All RJ-45 ports support Auto MDI Function
•
Embedded 8*10/100Tx (PSE 30W/Port) RJ45 Ports, 2*10/100/1000Tx RJ45, and
2*100/1000 SFP Slots
•
Store-and-forward switching architecture
•
8K MAC address table
•
Power line EFT protection: 2,000VDC; Ethernet ESD protection: 6,000VDC
Power Input
•
DC 48~55V 5.5A redundant with a 6-pin removal terminal block
•
One user programmable alarm relay contact 24 VDC, 1A resistive
•
The power input specification is complied with the requirements of SELV (Safety Extra Low
Voltage), and the power supply should be complied with UL 61010-1 & UL 61010-2-201
Operating Temperature
•
LMP-1202M-SFP: -10°C to 70°C
•
LMP-1202M-SFP-T: -40°C to 75°C
Case/Installation
•
IP-30 protection metal housing
•
DIN-Rail and wall mount design
•
Installation in a Pollution Degree 2 industrial environment