LMP-1202M-SFP Series Hardware Manual V1.0
iv
ATEX Certification
ATEX Marking String:
II 3G Ex nA nC IIC T4 Gc
ATEX Certificate No.:
DEMKO 18 ATEX 2104X
Standards:
EN 60079-0:2012 + A11:2013, EN 60079-15:2010
Temperature code:
T4
Specific Conditions of Use
•
The equipment shall be installed in an enclosure that provides a degree of protection not less than IP 54 in
accordance with EN 60079-15 and accessible only by the use of a tool. In addition, the equipment shall only be
used in an area of not more than pollution degree 2 as defined in EN 60664-1.
•
Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more
than 140%.
•
Conductors suitable for use in an ambient temperature of 105.7°C must be used for the Power Supply Terminal
•
The external grounding conduct shall be at least 4 mm
2
.
WARNING
: EXPLOSION HAZARD – Do not disconnect while the circuit is live or unless the area is free of ignitable
concentrations.