Antaira Technologies - Industrial Ethernet Switches
LMP-1002G-10G-SFP-24 Hardware Manual V1.0
7
There is a ‘Reset’ button located on the front panel of the industrial Ethernet switch that
helps users to reboot, restore default, or save running configurations by pressing the
button for different seconds. Please refer to
Table 2.2
for the timing and function.
Seconds
Function
1
Save running configuration to USB
4-6
Reboot the switch
7 or more
Restore factory default
Table 2.2
– Reset Button Functions
2.6 Ethernet Ports
RJ-45 Ports
RJ-45 Ports (Auto MDI/MDIX)
: The RJ-45 ports are auto-sensing for 10Base-T, 100Base-
TX, or 1000Base-T connections. Auto MDI means that the switch can connect to another
switch or workstation without changing the straight-through or crossover cabling. See the
figures below for straight-through and crossover cabling schematics.
RJ-45 Pin Assignments
Pin Number
Assignment
1
Rx+
2
Rx-
3
Tx+
6
Tx-
Table 2.3 - RJ45 Pin Assignments
Note:
The
“+” and “-” signs represent the polarity of the wires that make up each wire pair.
All ports on this industrial Ethernet switch support automatic MDI operations. Users can use
straight-through cables (see figure below) for all network connections to PCs, servers, and
other switches or hubs. With straight-through cabling, pins 1, 2, 3, and 6 are at one end of
the cable and are connected straight through to pins 1, 2, 3 and 6 at the other end of the
cable. The table below (
Table 2.4
) shows the 10BASE-T/100BASE-TX/1000BASE-T MDI
port pin outs
Pin MDI-X
Signal Name
MDI Signal Name
1
Receive Data plus (RD+)
Transmit Data plus (TD+)
2
Receive Data minus (RD-)
Transmit Data minus (TD-)
3
Transmit Data plus (TD+)
Receive Data plus (RD+)
6
Transmit Data minus (TD-)
Receive Data minus (RD-)
Table 2.4 - Ethernet Signal Pin