Pin MDI-X 

Signal Name 

MDI Signal Name 

Receive Data plus (RD+) 

Transmit Data plus (TD+) 

Receive Data minus (RD-) 

Transmit Data minus (TD-) 

Transmit Data plus (TD+) 

Receive Data plus (RD+) 

Transmit Data minus (TD-) 

Receive Data minus (RD-) 

Table 2.4 - Ethernet Signal Pin 

 

The following figures show the cabling schematics for straight-through and crossover. 

 

 

2.7 Cabling 

Use the four twisted-pair, category 5e, or the above cabling for the RJ-45 port connections. The cable 

between the switch and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 

ft.) in length. 

The small form-factor pluggable (SFP) is a compact optical transceiver used in optical communications for both 

telecommunication and data communication applications. 

 

Caution:

 Please employ optional optical transceiver (SFP/Fixed Fiber) that complies with IEC-60825-1 and 

classified as Class 1 laser product. 

 

Attention:

 Veuillez utiliser un émetteur-récepteur optique en option (SFP/fibre fixe) conforme à la norme IEC-

60825-1 et classé comme produit laser de classe 1. 

 

 

 

 

 

 

Figure 2.4 - Straight-Through Cables Schematic     Figure 2.5 - Crossover Cables Schematic 

Summary of Contents for LMP-0702G-SFP-24-V2 Series

Page 1: ...Series 7 Port Industrial Gigabit PoE Light Layer 3 Managed Ethernet Switch w 4 10 100 1000Tx 30W Port 1 10 100 1000Tx and 2 100 1000 SFP Slots 12 55VDC Power Input Version 2 Hardware Hardware Manual V...

Page 2: ...owners Notice Copyrights 2020 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowe...

Page 3: ...ssly approved by the grantee of this device could void the user s authority to operate the equipment Avertissement FCC Cet quipement a t test et d clar conforme aux limites d un appareil num rique de...

Page 4: ...red to take adequate measures Avertissement de marque CE Ceci est un produit de classe A Dans un environnement domestique ce produit peut provoquer des interf rences radio auquel cas l utilisateur peu...

Page 5: ...ty Precaution 3 2 Hardware Description 4 2 1 Physical Dimensions 4 2 2 Front Panel 5 2 3 Top View 5 2 4 LED Indicators 6 2 5 Reset Button 7 2 6 Ethernet Ports 7 2 7 Cabling 8 2 8 Wiring the Power Inpu...

Page 6: ...ndard ITU T G 8032 ERPS Ethernet Ring Protection Switch protocol that has a 50ms network recovery time The advanced network filtering and security functions such as IGMP VLAN QoS SNMP RMON Modbus TCP...

Page 7: ...eatures System Interface and Performance All RJ45 ports support Auto MDI MDI X Function Embedded 4 10 100 1000Tx PSE 30W Port RJ45 ports 1 10 100 1000Tx RJ45 port and 2 100 1000 SFP slots Store and fo...

Page 8: ...veuillez utiliser un dispositif de protection sur l entr e d alimentation Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage du commutateur Ethernet ind...

Page 9: ...P 24 V2 Series Hardware Manual V1 0 4 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira s LMP 0702G SFP 24 V2 series W x D x H is 54mm x 99mm x 1...

Page 10: ...uipped with one 6 pin removal terminal block connector for dual DC power inputs 48 55VDC Figure2 3 Top Panel View of LMP 0702G SFP 24 V2 Series Reset Button LED for Power 1 Power 2 Fault Master and Ri...

Page 11: ...g Green On ERPS Ring Network is active Flashing ERPS Ring Network works abnormally or misconfigure Off ERPS Ring Network is not active SFP Port 6 7 Green 1000Mbps Amber 100Mbps On Connected to Network...

Page 12: ...MDI MDIX The RJ 45 ports are auto sensing for 10Base T 100Base TX or 1000Base T connections Auto MDI means that the switch can connect to another switch or workstation without changing the straight th...

Page 13: ...cabling for the RJ 45 port connections The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft in length The small form factor pluggable SFP i...

Page 14: ...o the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 6 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 7 C...

Page 15: ...ure managed industrial switch only and form a normal open circuit An example is shown below in Figure 2 8 Caution The wire gauge for the terminal block should range between 12 24 AWG If only using one...

Page 16: ...ctromagnetic Interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices The grounding screw symbol is shown blow in Figure 2 15 Figure 2 15 G...

Page 17: ...Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l appareil est de 3 5 pouces livres 2 To remove the DIN Rail bracket do the opposit...

Page 18: ...ounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Caution The torque for tightening the scr...

Page 19: ...ion If you want to wall mount the industrial Ethernet switch please refer to the Wall Mounting section for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall ple...

Page 20: ...age Power lines should be properly insulated as well as other cables Be careful when handling them so as to not trip over Do not under any circumstance insert foreign objects of any kind into the heat...

Page 21: ...v2 50ms Configuration Http Https Telnet SSH CLI TFTP SNMP v3 System Diagnostics Dual Image Protection PING PING6 Switch Properties Back Plane Switching Fabric Non blocking Priority Queues 8 Processing...

Page 22: ...to 65 C EOT 40 C to 75 C Storage Temperature 40 C to 85 C Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals EMI FCC Part 15 Subpart B Class A CE EN55032 EN61000 6 4 Class A EMS CE...