5. Trouble Shooting
•
Always verify the right power cord or adapter is being used. Never use a power supply or
adapter with a non-compliant DC output voltage or it will burn the equipment.
•
Select the proper UTP or STP cable in order to construct the network. Use an Unshielded
Twisted-Pair (UTP) or Shield Twisted-Pair (STP) cable for RJ-45 conne
ctions: 100Ω
Category 5e for 10/100/1000Mbps. Also be sure that the length of any twisted-pair
connection does not exceed 100 meters (328 feet).
•
Diagnosing LED Indicators:
To assist in identifying problems, the media converter can be
easily monitored with the LED indicators which help to identity if any problems exist.
o
Please refer to the LED Indicators section for LED light indication information.
•
If the power indicator LED does not turn on when the power cord is plugged in, the user
may have a problem with the power cord. Check for loose power connections, power losses
or surges at the power outlet.
o
Please contact Antaira for technical support if the problem cannot be resolved.
•
If the industrial media converter LED indicators are normal and the connected cables are
correct but the packets still cannot transmit, please check the system’s Ethernet devices’
configuration or status.